SROS Command Line Interface Reference Guide
Demand Interface Configuration Command Set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
827
connect-sequence interface-recovery [retry-interval
<seconds>
|
max-retries
<value>
]
Use the
connect-sequence interface-recovery
command to allow the interface to go down in the event
that the
connect-sequence attempts
connect-sequence attempts <value>
page 826 for more information. Use the
no
form of this command to restore the default values.
Syntax Description
retry-interval
<seconds>
Optional. Specifies the number of seconds the interface will wait between
connect sequence cycles during recovery attempts.
max-retries
<value>
Optional. Specifies the maximum number of times the connect sequence will
cycle in an attempt to bring the interface back up. When in interface recovery
mode, this value overrides the
connect-sequence attempts
value.
Default Values
By default, the
connect-sequence interface-recovery retry-interval
is set to 120 seconds and
max-retries
are unlimited.
Usage Examples
The following example configures demand interface
1
to wait
60
seconds between retry attempts with a
maximum number of
500
retries:
ProCurve(config)#
interface demand 1
ProCurve(config-demand 1)#
connect-sequence interface-recovery retry-interval 60 max-retries 500