ctrl-subvol
is the name of an RDF subsystem control subvolume.
Cause
The RDF subsystem that you specified as your network master has not been configured
as a network master.
Effect
Validation fails.
Recovery
You need to reconfigure your local subsystem and specify the control subvolume
of your network master. You might also need to reconfigure your network master.
RDF subsystem ctrl-subvol stopped. TMF audit trails remain pinned.
ctrl-subvol
is the name of an RDF subsystem control subvolume.
Cause
The user issued a STOP RDF command for the RDF subsystem with the specified
control subvolume.
Effect
The RDF product has stopped, but the TMF product continues to pin audit trail files
on behalf of the RDF product.
Recovery
If you intend to restart the RDF product, no recovery action is necessary.
If you intend to delete the RDF configuration, then you must issue an RDFCOM UNPINAUDIT
command. Failure to do this could cause TMF to run out of audit trail space.
RDFCOM internal error in handling prompt
Cause
RDFCOM detected an internal error in handling your response to the RDFCOM
prompt.
Effect
The attempted command is aborted.
Recovery
Contact the Global Mission Critical Solution Center (GMCSC) or your service
provider.
RDFCOM is asking the TMP to restore the file. If the file was previously
dumped to tape, watch for the TMP to tell you to mount the appropriate
tape.
Cause
In response to a prompt, you requested RDFCOM to trigger restoration of an audit
trail file. If the file has been previously dumped to tape, you must now watch the EMS log for
the TMP’s prompt to mount the appropriate tape.
Effect
The restore operation proceeds.
Recovery
When the tape-mount prompt appears in the EMS log, mount the tape.
RDFNETS process only allowed for RDF network master configuration.
Cause
You have attempted to add the NetSynch process to your configuration, but your
configuration is not the network master.
Effect
The configuration command fails.
Recovery
Do not add this record.
RDFVOLUME in network master record is incorrect rdf-vol.
rdf-vol
is the RDFVOLUME specified in the network record of the network master.
Cause
The RDFVOLUME of the current RDF configuration does not match the value specified
in the network record of the network master.
Effect
Validation fails.
Recovery
You must reconfigure your network master and possibly your local configuration.
RDFVOLUME in network master record is invalid.
Cause
The RDFVOLUME of the current RDF configuration is invalid in the network record
of the network master.
RDFCOM Messages
439
Содержание NonStop RDF
Страница 68: ...68 ...
Страница 186: ...186 ...
Страница 260: ...260 ...
Страница 278: ...278 ...
Страница 284: ...284 ...
Страница 290: ...290 ...
Страница 308: ...308 ...
Страница 322: ...322 ...
Страница 336: ...336 ...
Страница 348: ...348 ...
Страница 464: ...464 ...
Страница 478: ......