Recovery
Correct the STARTUPMSG attribute script and then manually delete the RDF
lockstep gateway process from SCF and run your newly edited SCF script. The process name
must not include a node name.
32
A spurious STARTUPMSG argument was encountered for the lockstep gateway.
Cause
In your SCF script for starting the lockstep gateway, the STARTUPMSG attribute
contained an extra or unrecognizable argument.
Effect
The lockstep gateway stops.
Recovery
The STARTUPMSG attribute must include exactly two arguments: the word
ENABLE or DISABLE, and a valid RDF extractor process name, all enclosed in quotes. Correct
the STARTUPMSG attribute script and then manually delete the RDF lockstep gateway process
from SCF and run your newly edited SCF script. The process name must not include a node
name.
Lockstep Gateway Event Messages
321