Cause
The COPYAUDIT command could not find any image files on the remote image trail.
This problem indicates that the receiver’s RETAINCOUNT value was probably not set high
enough and that, as a result, some image files on the remote system were purged.
Effect
The COPYAUDIT command aborts.
Recovery
There is no recovery action. The COPYAUDIT command cannot be executed
because image files needed for this command were already purged from the remote system.
No MONITOR is Configured
Cause
The RDF configuration file is invalid.
Effect
The validation fails.
Recovery
Alter the configuration to include the monitor.
No PCB available
Cause
A NEWPROCESS error occurred during START RDF or TAKEOVER processing.
Effect
The command fails.
Recovery
Check system resource utilization. When resources become available, reenter the
command.
No RECEIVER is Configured
Cause
The RDF configuration file is invalid.
Effect
The configuration validation fails.
Recovery
Check the receiver parameter entries in the configuration file for invalid values
and correct any errors found.
No VOLUMEs are configured
Cause
The RDF configuration file is invalid.
Effect
The configuration validation fails.
Recovery
Check the updater process parameters in the configuration file for invalid values
and correct any errors found.
No VOLUMES are configured for ATINDEX atindex
Cause
You added an extractor and receiver with the specified ATINDEX, but there are no
updaters with that value.
Effect
The validation fails.
Recovery
Add at least one updater with the same ATINDEX value or delete the particular
extractor-receiver pair.
Obtained error error# in attempting to examine remote imagetrail files
error#
is the file-system error number that identifies the specific error.
Cause
The COPYAUDIT command encountered the specified error in attempting to read
the remote image trail files.
Effect
The command fails.
Recovery
See the Operator Messages Manual for a description of the error code. For additional
details about understanding and correcting file-system errors, see the Guardian Procedure Errors
and Messages Manual. If possible, correct the error and reenter the COPYAUDIT command.
Otherwise, see your system manager.
Only one Network record is allowed for a non-network master
Cause
Your current RDF configuration does not have the NetworkMaster attribute set and
you have tried to add more than one network record.
Effect
The configuration command fails.
RDFCOM Messages
433
Содержание NonStop RDF
Страница 68: ...68 ...
Страница 186: ...186 ...
Страница 260: ...260 ...
Страница 278: ...278 ...
Страница 284: ...284 ...
Страница 290: ...290 ...
Страница 308: ...308 ...
Страница 322: ...322 ...
Страница 336: ...336 ...
Страница 348: ...348 ...
Страница 464: ...464 ...
Страница 478: ......