7-8
HP Netserver AA Solution Administrator’s Guide
Running MTCFLASH
Before you run MTCFLASH, note that:
•
In an Endurance server, all MICs (CE and IOP)
must
use the same MIC firmware
revisions.
•
After running MTCFLASH, you
must
reboot the computer that you are updating, either
by using the reset button or by powering the machine off and then on again.
Warning:
Before removing power to any computer, observe all necessary
precautions to maintain Endurance server availability.
•
To run MTCFLASH on a CE, make sure that a keyboard is physically attached to the CE,
or select a CE port if you are using a KVM switch.
•
You must create an MTC diskette (described on
page 7-15
) using the
correct
Endurance
CD. For example, consider the following when creating an MTC diskette:
Table 7-2 Creating the MTC Diskette for Running MTCFlash
If running MTCFLASH . . .
Create the MTC Diskette . . .
Notes
When initially installing an
Endurance server
Using the Endurance CD that was
shipped with your Endurance server or
an Endurance hotfix diskette if one is
applicable to this release.
Refer to the HP
Customer Support
web site for
information about
hotfixes that might be
applicable to your
release.
Содержание NetServer AA 6200
Страница 1: ...HP Netserver AA Solution Administrator s Guide HP Part Number 5971 3014 Printed in April 2001 ...
Страница 8: ......
Страница 11: ...Tables xi A 3 Firmware LED A 3 A 4 Fiber LEDs A 4 ...
Страница 12: ......
Страница 14: ......
Страница 18: ...xviii HP Netserver AA Solution Administrator s Guide ...
Страница 88: ......
Страница 180: ...6 8 HP Netserver AA Solution Administrator s Guide Figure 6 2 Sample Endurance Configuration ...
Страница 210: ......
Страница 216: ......
Страница 248: ......
Страница 256: ......
Страница 262: ......