Table 7-2 Typical Server Configurations for the HP 9000 rp7440 Server
(continued)
Typical
Cooling
Typical
Power
Bulk Power
Supplies
Core I/O
Hard Disk
Drives
DVDs
PCI Cards
(assumes 10
watts each)
Memory Per
Cell Board
Cell
Boards
BTU/hr
Watts
Qty
Qty
Qty
Qty
Qty
GBytes
Qty
6389
1871
2
2
2
2
8
8
2
4224
1237
2
1
1
1
8
8
1
The air conditioning data is derived using the following equations.
•
Watts x (0.860) = kcal/hour
•
Watts x (3.414) = Btu/hour
•
Btu/hour divided by 12,000 = tons of refrigeration required
NOTE:
When determining power requirements you must consider any peripheral equipment
that will be installed during initial installation or as a later update. Refer to the applicable
documentation for such devices to determine the power and air-conditioning that is required to
support these devices.
Boot Console Handler (BCH) for the HP Integrity rx7640 and HP 9000
rp7440 Servers
Booting an HP 9000 sx2000 Server to BCH
After you power on the server or use the management processor (MP)
BO
command to boot an
nPartition past boot-is-blocked (BIB), the nPartition console will show activity while the firmware
is initialized and will stop at the BCH Main Menu (the
Main Menu: Enter command or
menu>
prompt).
Use the BCH
DI
command to redisplay the current menu and its available commands.
Main Menu: Enter command or menu > di
---- Main Menu ---------------------------------------------------------------
Command Description
------- -----------
BOot [PRI|HAA|ALT|<path>] Boot from specified path
PAth [PRI|HAA|ALT] [<path>] Display or modify a path
SEArch [ALL|<cell>|<path>] Search for boot devices
ScRoll [ON|OFF] Display or change scrolling capability
COnfiguration menu Displays or sets boot values
INformation menu Displays hardware information
SERvice menu Displays service commands
DIsplay Redisplay the current menu
HElp [<menu>|<command>] Display help for menu or command
REBOOT Restart Partition
RECONFIGRESET Reset to allow Reconfig Complex Profile
----
Main Menu: Enter command or menu >
For information about any of the available BCH commands, use the
HE
command.
HP-UX for the HP Integrity rx7640 and HP 9000 rp7440 Servers
HP supports nPartitions on cell-based HP 9000 servers. The HP 9000 rp7440 Server runs HP-UX
11i Version 1 (B.11.11).
178
HP Integrity rp7440 Server
Содержание Integrity rx7640
Страница 8: ...8 ...
Страница 12: ...12 ...
Страница 13: ...List of Examples 4 1 Single User HP UX Boot 101 7 1 Single User HP UX Boot 181 13 ...
Страница 14: ...14 ...
Страница 42: ...42 ...
Страница 88: ...88 ...
Страница 130: ...Figure 5 8 Core I O Button Locations OLR MP Reset 130 Server Troubleshooting ...
Страница 140: ...140 ...
Страница 176: ...176 ...
Страница 184: ...184 ...
Страница 191: ...Figure C 3 Planning Grid Computer Room Layout Plan 191 ...
Страница 192: ...Figure C 4 Planning Grid 192 Templates ...