Figure 5-3 PCI-X Power Supply LED Locations
1
2
Table 5-3 PCI Power Supply LEDs
Description
State
Driven By
LED
All output voltages generated by the power supply are
within limits.
On Green
Each supply
Power
1
Power to entire system has been removed.
Off
The temperature within the power supply is above the
lower threshold.
Flash Yellow
Each supply
Fault
2
The temperature of the power supply is approaching the
thermal limit.
On Yellow
Power supply has shut down due to an over temperature
condition, a failure to regulate the power within expected
limits, or a current-limit condition.
Flash Red
Normal operation.
Off
System and PCI I/O Fan LEDs
There is a single three-color LED on each system and PCI I/O fan.
Server LED Indicators
125
Содержание Integrity rx7640
Страница 8: ...8 ...
Страница 12: ...12 ...
Страница 13: ...List of Examples 4 1 Single User HP UX Boot 101 7 1 Single User HP UX Boot 181 13 ...
Страница 14: ...14 ...
Страница 42: ...42 ...
Страница 88: ...88 ...
Страница 130: ...Figure 5 8 Core I O Button Locations OLR MP Reset 130 Server Troubleshooting ...
Страница 140: ...140 ...
Страница 176: ...176 ...
Страница 184: ...184 ...
Страница 191: ...Figure C 3 Planning Grid Computer Room Layout Plan 191 ...
Страница 192: ...Figure C 4 Planning Grid 192 Templates ...