Scenario 3:1 – Multi-Enclosure stacking, with Multiple Simple vNets, Redundant Uplinks and LACP (2 Enclosures) 179
Figure 3-10
Define Ethernet Network (vNet-PROD-2).
Note: The uplinks are connected to different enclosures, (enc0 and enc1).
Defining a Server Profile with NIC Connections, via GUI
Each server NIC will connect to a specific network.
On the Virtual Connect Manager screen, click Define, Server Profile to create a Server Profile
•
Create a server profile called “App-1”
Defining a Server Profile with NIC Connections, via GUI
Each server NIC will connect to a specific network.
On the Virtual Connect Manager screen, click Define, Server Profile to create a Server Profile
•
Create a server profile called “App-1”
•
In the Network Port 1 drop down box, select “vNet-PROD”
•
In the Network Port 2 drop down box, select “vNet-PROD”
•
In the Assign the Profile to a Server Bay, select Bay 1 and apply
Defining a Server Profile with NIC Connections, via CLI
The following command(s) can be copied and pasted into an SSH based CLI session with Virtual Connect
# Create and Assign Server Profile App-1 to server bay 1
add profile App-1 –nodefaultenetconn
add enet-connection App-1 pxe=Enabled
add enet-connection App-1 pxe=Disabled
set enet-connection App-1 1 Network=vNet-PROD-1
set enet-connection App-1 2 Network=vNet-PROD-2
assign profile App-1 enc0:1