Hardware options installation 39
13.
Remove the fan blanks from locations 1 and 2. For fan location and numbering information, see
"Hot-plug fans (on page
)" or the label attached to the chassis next to the fans.
14.
Install the fans into locations 1 and 2.
IMPORTANT:
Do not mix standard fans and high-performance fans in the same server.
15.
Install the access panel (on page
16.
Install the server into the rack.
17.
Connect each power cord to the server.
18.
Connect each power cord to the power source.
19.
Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED
changes from amber to green.