Hardware options installation  43 

Type 

Rank 

Capacity (GB) 

Native speed 
(MT/s) 

Voltage 

LRDIMM 

Quad 

64 

2400 

STD 

LRDIMM 

Octal 

128 

2400 

STD 

Populated DIMM speed (MT/s)

 

Populated DIMM speed — Intel Xeon E5-2600 v3 processor installed 

Type 

Rank 

Capacity 
(GB) 

1 DIMM per 
channel (MT/s) 

2 DIMMs per 
channel (MT/s) 

3 DIMMs per 
channel (MT/s) 

RDIMM 

Single 

4 or 8 

2133 

2133 

1600 

RDIMM 

Dual 

8, 16, or 32 

2133 

2133 

1600 

LRDIMM 

Dual 

16 

2133 

2133 

1866 

LRDIMM 

Quad 

32 or 64 

2133 

2133 

1866 

Populated DIMM speed — Intel Xeon E5-2600 v4 processor installed 

Type 

Rank 

Capacity 
(GB) 

1 DIMM per 
channel (MT/s) 

2 DIMMs per 
channel (MT/s) 

3 DIMMs per 
channel (MT/s) 

RDIMM 

Single 

8 or 16 

2400 

2133 

1866 

NVDIMM-N 
(RDIMM) 

Single 

2133 

1866 

1600 

RDIMM 

Dual 

16 or 32 

2400 

2400 

1866 

LRDIMM 

Dual 

32 

2400 

2400 

2400 

LRDIMM 

Quad 

64 

2400 

2400 

2400 

LRDIMM 

Octal 

128 

2400 

2400 

2400 

The operating memory speed is a function of the rated DIMM speed, DIMMs installed per channel, 
processor model, and the speed selected in the BIOS/Platform Configuration (RBSU) of the UEFI System 
Utilities. 

Depending on the processor model, the number of DIMMs installed, and whether LRDIMMs or RDIMMs 
are installed, the memory clock speed can be reduced to 1866 MT/s. 

Maximum memory capacity

 

The maximum memory capacity is a function of the DIMM capacity, number of installed DIMMs, number 
of NVDIMMs, memory type, and number of installed processors. 

Maximum memory capacity — Intel Xeon E5-2600 v3 processor installed 

DIMM type 

DIMM rank 

Capacity (GB)  One processor (GB) 

Two processors (GB) 

RDIMM 

Single 

48 

96 

RDIMM 

Single 

96 

192 

RDIMM 

Dual 

96 

192 

RDIMM 

Dual 

16 

192 

384 

RDIMM 

Dual 

32 

384 

768 

LRDIMM 

Dual 

16 

192 

384 

LRDIMM 

Dual 

32 

384 

768 

LRDIMM 

Quad 

64 

768 

1536 

Maximum memory capacity — Intel Xeon E5-2600 v4 processor installed 

Содержание BCDVideo BCD108

Страница 1: ...R OEM USER GUIDE This document is for the person who installs administers and troubleshoots servers and storage systems BCDVIDEO assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels ...

Страница 2: ...prise website Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise website Microsoft Windows and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Linux is the registered trademark of Linus Torvalds in the U S and other countries Red Hat is a regi...

Страница 3: ...he access panel 22 Install the access panel 22 Remove the hot plug fan 22 Remove the PCI riser cage 23 Install the PCI riser cage 24 Removing the 8 SFF drive backplane 25 Setup 26 Optional services 26 Optimum environment 26 Space and airflow requirements 26 Temperature requirements 27 Power requirements 27 Electrical grounding requirements 28 Connecting a DC power cable to a DC power source 28 Rac...

Страница 4: ...rial cable option 90 Expansion board options 91 Removing the expansion slot blanks 91 Installing an expansion board 93 Location discovery services ear option 94 M 2 SSD Enablement Board option 100 Installing an SSD module on the M 2 SSD Enablement Board 100 Installing an M 2 SSD Enablement Board 101 Dual 8Gb microSD Enterprise Midline USB device 104 750 W Flex Slot Hot Plug Battery Backup Module 1...

Страница 5: ...ware and firmware 132 Operating System Version Support 132 Version control 132 Operating systems and virtualization software support for ProLiant servers 133 HPE Technology Service Portfolio 133 Change control and proactive notification 133 Troubleshooting 135 Troubleshooting resources 135 Battery replacement 136 Warranty and regulatory information 137 Warranty information 137 Regulatory informati...

Страница 6: ...ower supply calculations 145 Support and other resources 146 Accessing Hewlett Packard Enterprise Support 146 Information to collect 146 Accessing updates 146 Websites 146 Customer Self Repair 147 Remote support 154 Acronyms and abbreviations 155 Documentation feedback 159 Index 160 ...

Страница 7: ...nal 3 USB 2 0 connector optional 4 Optical drive optional 5 Systems Insight Display optional 6 USB 3 0 connector 7 SAS SATA SSD drive bays 4LFF Item Description 1 Optical drive optional 2 Serial label pull tab 3 Front video connector optional 4 USB 2 0 connector optional 5 Systems Insight Display optional 6 USB 3 0 connector 7 SAS SATA SSD drive bays ...

Страница 8: ...k active Off No network activity 4 UID button LED Solid blue Activated Flashing blue 1 Hz cycle per sec Remote management or firmware upgrade in progress 4 Hz cycle per sec iLO manual reboot sequence initiated 8 Hz cycle per sec iLO manual reboot sequence in progress Off Deactivated When all four LEDs described in this table flash simultaneously a power fault has occurred For more information see ...

Страница 9: ...stem on Flashing green 1 Hz cycle per sec Performing power on sequence Solid amber System in standby Off No power present When all four LEDs described in this table flash simultaneously a power fault has occurred For more information see Power fault LEDs on page 10 Facility power is not present power cord is not attached no power supplies are installed power supply failure has occurred or the powe...

Страница 10: ...rt SAS HBA controller 6 flashes System board PCIe slots 7 flashes Power backplane or storage backplane 8 flashes Power supply 9 flashes Systems Insight Display LEDs The Systems Insight Display LEDs represent the system board layout The display provides status for all internal LEDs and enables diagnosis with the access panel installed To view the LEDs access the Systems Insight Display Description ...

Страница 11: ...a health event Combinations of illuminated Systems Insight Display LEDs the system power LED and the health LED indicate system status Systems Insight Display LED and color Health LED System power LED Status Processor amber Red Amber One or more of the following conditions may exist Processor in socket X has failed Processor X is not installed in the socket Processor X is unsupported ROM detects a...

Страница 12: ...through hot plug addition Power cap off Amber Standby Power cap green Flashing green Waiting for power Power cap green Green Power is available Power cap flashing amber Amber Power is not available IMPORTANT If more than one DIMM slot LED is illuminated further troubleshooting is required Test each bank of DIMMs by removing all other DIMMs Isolate the failed DIMM by replacing each DIMM in a bank w...

Страница 13: ...g managed remotely Off Identification is deactivated 2L iLO 4 standard NIC activity LED Solid green Activity exists Flashing green Activity exists Off No activity exists 2R iLO 4 standard NIC link LED Solid green Link exists Off No link exists 3 Power supply 2 LED Solid green Normal Off One or more of the following conditions exists AC power unavailable Power supply failed Power supply in standby ...

Страница 14: ...er 4 System maintenance switch 5 Front VGA USB 2 0 connector 6 x4 SATA port 1 7 x4 SATA port 2 8 Backplane presence detect connector 9 Optical SATA port 5 10 SATA port 4 11 Front power USB 3 0 connector 12 HPE Smart Storage Battery connector 13 Optional Location Discovery Services connector 14 Drive backplane power connector 15 microSD card slot 16 Dual internal USB 3 0 connector 17 Smart Array HB...

Страница 15: ...enance switch position 6 is set to the On position and Secure Boot is enabled some configurations cannot be restored For more information see Secure Boot configuration on page 127 IMPORTANT Before using the S7 switch to change to Legacy BIOS Boot Mode be sure the HPE Dynamic Smart Array B140i Controller is disabled Do not use the B140i controller when the server is in Legacy BIOS Boot Mode NMI jum...

Страница 16: ...described in this section indicates a possible error Item LED definitions 1 Fast flashing blue A backup is in progress Do not remove the NVDIMM Slow flashing blue 1 flash 15 seconds Normal operation 2 Reserved 3 Solid or flashing green Power is available to the NVDIMM Do not remove the NVDIMM Off Power is not available to the NVDIMM PCIe riser board slot definitions Primary riser cage connector co...

Страница 17: ... riser This conversion requires a second processor to be installed Notes Primary denotes the riser cage is installed in the primary riser connector Secondary denotes the riser cage is installed in the secondary riser connector Installing the riser cages listed in the table above in either the primary or secondary riser connectors determines the form factor of the PCI cards supported by those riser...

Страница 18: ...ty ring Rotating green Drive activity Off No drive activity 3 Do not remove Solid white Do not remove the drive Removing the drive causes one or more of the logical drives to fail Off Removing the drive does not cause a logical drive to fail 4 Drive status Solid green The drive is a member of one or more logical drives Flashing green The drive is rebuilding or performing a RAID migration strip siz...

Страница 19: ... Removal of the NVMe SSD before the device has completed and ceased signal traffic flow can cause loss of data Item Description 1 Release lever 2 Activity ring 3 Do Not Remove button 4 Power button Hot plug fans CAUTION To avoid damage to server components fan blanks must be installed in fan bays 1 and 2 in a single processor configuration The only two valid fan configurations are listed in the fo...

Страница 20: ...s The fans operate at minimum speed until a temperature change requires a fan speed increase to cool the server The server shuts down during the following temperature related scenarios At POST and in the OS iLO 4 performs an orderly shutdown if a cautionary temperature level is detected If the server hardware detects a critical temperature level before an orderly shutdown occurs the server perform...

Страница 21: ...tiates a controlled remote shutdown of applications and the OS before the server enters standby mode Before proceeding verify that the server is in standby mode by observing that the system power LED is amber Extend the server from the rack NOTE If the optional cable management arm option is installed you can extend the server without powering down the server or disconnecting peripheral cables and...

Страница 22: ...UTION Do not operate the server for long periods with the access panel open or removed Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage To remove the component 1 Power down the server on page 21 2 Extend the server from the rack on page 21 3 Open or unlock the locking latch slide the access panel to the rear of the chassis and rem...

Страница 23: ... improper cooling that can lead to thermal damage IMPORTANT For optimum cooling install fans in all primary fan locations For more information refer to the fan locations table To replace the component reverse the removal procedure Remove the PCI riser cage 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 ...

Страница 24: ...5 Remove the PCI riser cage Install the PCI riser cage 1 Install the PCI riser cage 2 Install the access panel on page 22 3 Install the server into the rack 4 Connect each power cord to the server 5 Connect each power cord to the power source 6 Power up the server Powering up the server on page 21 ...

Страница 25: ...r from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove all drives Removing a hot plug SAS or SATA drive on page 55 6 Remove all drive blanks Removing the hard drive blank on page 54 7 Disconnect and remove all cables connected to the drive backplane 8 Remove the 8SFF SAS SATA drive backplane ...

Страница 26: ...Startup and implementation services for both hardware and software HPE Education Services Help train your IT staff For more information on HPE support services see the Hewlett Packard Enterprise website http www hpe com services Optimum environment When installing the server in a rack select a location that meets the environmental standards described in this section Space and airflow requirements ...

Страница 27: ... panels of the rack must be a minimum of 7 cm 2 75 in Temperature requirements To ensure continued safe and reliable equipment operation install or position the system in a well ventilated climate controlled environment The maximum recommended ambient operating temperature TMRA for most server products is 35 C 95 F The temperature in the room where the rack is located must not exceed 35 C 95 F For...

Страница 28: ...tional Electrotechnical Commission IEC Code 364 parts 1 through 7 Furthermore you must be sure that all power distribution devices used in the installation such as branch wiring and receptacles are listed or certified grounding type devices Because of the high ground leakage currents associated with multiple servers connected to the same power source Hewlett Packard Enterprise recommends the use o...

Страница 29: ... source requires ring tongues use a crimping tool to install the ring tongues on the power cord wires IMPORTANT The ring terminals must be UL approved and accommodate 12 gauge wires 3 Stack each same colored pair of wires and then attach them to the same power source The power cord consists of three wires black red and green For more information see the documentation that ships with the power supp...

Страница 30: ...following information when connecting peripheral cables and power cords to the server WARNING This server is heavy To reduce the risk of personal injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual material handling Get help to lift and stabilize the product during installation or removal especially when the product is not fastened ...

Страница 31: ...rial connector optional 13 USB 3 0 connectors 14 FlexibleLOM bay The slot 3 PCIe 3 riser is optional and requires a second processor before installation 3 Connect the power cord to the server 4 Use the hook and loop strap to secure the power cord 5 Connect the power cord to the power source Powering on and selecting boot options in UEFI Boot Mode On servers operating in UEFI Boot Mode the boot con...

Страница 32: ...gent Provisioning For single server deployment updating and provisioning capabilities To install an operating system on the server with Intelligent Provisioning local or remote a Connect the Ethernet cable between the network connector on the server and a network jack b Press the Power On Standby button c During server POST press F10 d Complete the initial Preferences and Registration portion of I...

Страница 33: ...ding can cause electrostatic discharge High performance fan option This kit is available to meet some extended ambient operating temperatures above 35 degrees Celsius For more information about the qualifications for extended ambient configurations see the Hewlett Packard Enterprise website http www hpe com servers ASHRAE To install the component 1 Power down the server on page 21 2 Remove all pow...

Страница 34: ...Hardware options installation 34 5 Remove all standard fans from the fan bays 6 Remove fan blanks from the fan bays if installed ...

Страница 35: ...sor and system board only authorized personnel should attempt to replace or install the processor in this server CAUTION To prevent possible server malfunction and damage to the equipment multiprocessor configurations must contain processors with the same part number IMPORTANT If installing a processor with a faster speed update the system ROM before installing the processor To install the process...

Страница 36: ...illustration and then open the processor retaining bracket 7 Remove the clear processor socket cover Retain the processor socket cover for future use CAUTION THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the system board do not touch the processor or the processor socket contacts ...

Страница 37: ...et When the processor is installed properly inside the processor retaining bracket the processor retaining bracket clears the flange on the front of the socket CAUTION Do not press down on the processor Pressing down on the processor might damage the processor socket and the system board Press only in the area indicated on the processor retaining bracket 10 Press and hold the processor retaining b...

Страница 38: ...processor and socket requiring system board replacement 11 Remove the heatsink cover CAUTION After the cover is removed do not touch the thermal interface media 12 Install the heatsink a Position the heatsink on the processor backplate b Tighten one pair of diagonally opposite screws halfway and then tighten the other pair of screws c Finish the installation by completely tightening the screws in ...

Страница 39: ...fans into locations 1 and 2 IMPORTANT Do not mix standard fans and high performance fans in the same server 15 Install the access panel on page 22 16 Install the server into the rack 17 Connect each power cord to the server 18 Connect each power cord to the power source 19 Press the Power On Standby button The server exits standby mode and applies full power to the system The system power LED chan...

Страница 40: ...s WARNING To reduce the risk of personal injury electric shock or damage to the equipment remove the power cord to remove power from the server Pressing the Power On Standby button does not shut off system power completely Portions of the power supply and some internal circuitry remain active until AC power is removed To install the component 1 Power down the server on page 21 2 Remove all power a...

Страница 41: ...all the server into the rack 11 Connect each power cord to the server 12 Connect each power cord to the power source 13 Press the Power On Standby button The server exits standby mode and applies full power to the system The system power LED changes from amber to green Memory options This server supports multiple DIMM types Regular RDIMMs LRDIMMs ...

Страница 42: ...orted by the server For the latest memory configuration information see the following resources The product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs HPE Server Memory Configurator https h22195 www2 hpe com DDR4memoryconfig Home Legal DIMM type Intel Xeon E5 2600 v3 processors support o Single rank and dual rank PC4 2133P DDR4 2133 RDIMMs operating at up to 2133...

Страница 43: ...d 64 2400 2400 2400 LRDIMM Octal 128 2400 2400 2400 The operating memory speed is a function of the rated DIMM speed DIMMs installed per channel processor model and the speed selected in the BIOS Platform Configuration RBSU of the UEFI System Utilities Depending on the processor model the number of DIMMs installed and whether LRDIMMs or RDIMMs are installed the memory clock speed can be reduced to...

Страница 44: ... DRAM NVDIMM Ns are supported in select HPE servers drawing power from the HPE Smart Storage Battery to perform the backup The HPE 8GB NVDIMM is an NVDIMM N For more information about NVDIMM Ns and persistent memory see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise Information Library http www hpe com info NVDIMM docs Operation stages for NVDIMM Ns While the server is powered on ...

Страница 45: ...is accessed while writing to or reading from the memory A dual rank DIMM is similar to having two single rank DIMMs on the same module with only one rank accessible at a time A quad rank DIMM is effectively two dual rank DIMMs on the same module Only one rank is accessible at a time The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM...

Страница 46: ...128 GB 2 Rank 1R Single rank 2R Dual rank 4R Quad rank 8R Octal rank 3 Data width on DRAM x4 4 bit x8 8 bit 4 Memory generation DDR4 5 Maximum memory speed 2400 MT s 6 CAS latency P 15 T 17 7 DIMM type R RDIMM registered L LRDIMM load reduced For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterpr...

Страница 47: ...ced ECC Provides up to 4 bit error correction This mode is the default option for this server Online spare memory Provides protection against failing or degraded DIMMs Certain memory is reserved as spare and automatic failover to spare memory occurs when the system detects a DIMM that is degrading This allows DIMMs that have a higher probability of receiving an uncorrectable memory error which wou...

Страница 48: ... copies the memory contents of the degraded rank to the online spare rank The server then deactivates the failing rank and automatically switches over to the online spare rank Mirrored memory configuration Mirroring provides protection against uncorrected memory errors that would otherwise result in server downtime Mirroring is performed at the channel level to one memory channel pair that can be ...

Страница 49: ...3 MT s For more information about server memory see the Hewlett Packard Enterprise website http www hpe com info memory Advanced ECC population guidelines For Advanced ECC mode configurations observe the following guidelines Observe the general DIMM slot population guidelines DIMMs may be installed individually Online spare population guidelines For Online Spare memory mode configurations observe ...

Страница 50: ...are properly grounded before beginning this procedure CAUTION Failure to properly handle DIMMs can cause damage to DIMM components and the system board connector Before installing memory on the server Verify that the memory is supported on the server For more information see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs Review the DIMM handling guideline...

Страница 51: ...rve the following guidelines Before seating the DIMM open the DIMM slot and align the DIMM with the slot To align and seat the DIMM use two fingers to hold the DIMM along the side edges To seat the DIMM use two fingers to apply gentle pressure along the top of the DIMM For more information see the Hewlett Packard Enterprise website http www hpe com support DIMM 20070214 CN Installing a DIMM The se...

Страница 52: ...a loss can occur when system components such as the processor or HPE Smart Storage Battery fails HPE Smart Storage battery is a critical component required to perform the backup functionality of NVDIMM It is important to take action when HPE Smart Storage Battery related failures occur Always follow best practices for ensuring data protection 1 Power down the server on page 21 2 Remove all power a...

Страница 53: ...n see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise Information Library http www hpe com info NVDIMM docs Drive options Depending on the configuration this server supports SAS SATA and NVMe drives For more information on drive support see Device bay numbering Device numbers on page 17 When adding hard drives to the server observe the following general guidelines The system automa...

Страница 54: ...AS or SATA drive The server can support 8 SAS or SATA hard drives in a SFF configuration or 10 drives in an SFF configuration with the optional hard drive cage In an LFF configuration the server can support 4 SAS or SATA hard drives To install the component 1 Remove the drive blank 2 Prepare the drive 3 Install the drive ...

Страница 55: ...a on the drive 3 Remove the drive Installing the NVMe drives NVMe drives are supported on this server when the 10SFF 6 NVMe 4 SAS SATA Express Bay Enablement Option and or the 2SFF Express Bay Drive Cage is installed For more information on which bays support NVMe drives see Device numbers on page 17 To install the drives CAUTION To prevent improper cooling and thermal damage do not operate the se...

Страница 56: ...lashes to indicate the device is still in use Removal of the NVMe SSD before the device has completed and ceased signal traffic flow can cause loss of data To remove the component 1 Press the Power button The Do Not Remove button LED illuminates and flashes Do not press the button while the LED is illuminated 2 When the Do Not Remove button LED is no longer flashing or illuminated press the Do Not...

Страница 57: ...e touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove the un...

Страница 58: ...tallation 58 6 Install the drive cage assembly and then tighten the three screws 7 Connect the data cables to the SATA storage connector the SATA optical storage drive connector and the backplane presence detect connector ...

Страница 59: ...server or the enclosure unless all drive and device bays are populated with either a component or a blank 9 Install drives or blanks in the empty drive bays 2SFF Express Bay drive backplane CAUTION To prevent damage to electrical components take the appropriate anti static precautions before beginning any system installation Improper grounding can cause electrostatic discharge ...

Страница 60: ...n page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove all drives Removing a hot plug SAS or SATA drive on page 55 and drive blanks Removing the hard drive blank on page 54 6 Disconnect and remove all cables connected to the drive backplane 7 Remove the universal media bay blank 8 Install the drive cage assembly then tighten the three screws 9 Remove t...

Страница 61: ... 1 of the primary PCI riser cage 11 Install the primary PCI riser cage Install the PCI riser cage on page 24 12 Connect the data cables from the Express Bay drive cage to port 3 on the Express Bay bridge card 13 Connect the power cable to the left power connector on the backplane ...

Страница 62: ...0 Press the Power On Standby button The server exits standby mode and applies full power to the system The system power LED changes from amber to green 4LFF Universal Media Bay option WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the ...

Страница 63: ...Hardware options installation 63 o 4 LFF optical drive blank o 4 LFF VGA USB blank 6 Install the universal media bay option o 4 LFF optical drive ...

Страница 64: ... After installing the 4 LFF optical drive connect the ODD cable to the rear of the drive o 4 LFF VGA USB 7 Route the cables along the edge of the system board and then connect the cables to the system board o 4 LFF VGA USB connections ...

Страница 65: ...ss panel on page 22 9 Slide the server into the rack 10 Connect all power cords to the server and then power up the server 8SFF Universal Media Bay option WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any i...

Страница 66: ...he server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove the universal media bay blank 6 Install the universal media bay option o 8SFF DVD RW VGA USB ...

Страница 67: ... system board and then connect the cables to the system board o 8SFF DVD RW VGA USB connections Connect the VGA USB cable to the Front VGA USB connector toward the rear of the system board Connect the SATA optical cable to the SATA optical storage drive connector o 8SFF VGA USB connections ...

Страница 68: ...p to six SFF NVMe SSDs and four SFF SAS drives SATA drives or SSDs The high performance fans and a controller such as the HPE Smart Array P440ar Controller must be installed when installing this option For more information about NVMe SSDs see the Hewlett Packard Enterprise website http www hpe com support NVMedrive_en For more information on supported drives and population rules see the server use...

Страница 69: ...tall the Express Bay Bridge card in slot 1 of the primary PCI riser cage 12 Install the primary PCI riser cage Install the PCI riser cage on page 24 13 Cable the 10SFF 6 NVMe 4 SAS SATA Express Bay Enablement Options 10SFF 6 NVMe 4 SAS SATA Express Bay Enablement Option cabling on page 114 14 Install the high performance fans High performance fan option on page 33 15 Install the NVMe drives Instal...

Страница 70: ...er on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove the primary PCI riser cage Remove the PCI riser cage on page 23 6 Install the GPU in the x16 slot in the primary PCI riser cage position The PCI riser cage assembly with the full length full height PCIe3 x16 riser slot is re...

Страница 71: ...Hardware options installation 71 7 Install the GPU support bracket 8 Install the riser cage ...

Страница 72: ...ersonal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21...

Страница 73: ...options installation 73 6 If installed remove the low profile riser board from the secondary riser board slot Remove the riser cage bracket from the primary PCIe riser cage 7 Lift and remove the riser cage latch ...

Страница 74: ...y P440ar Controller for 2 GPU configurations 726740 B21 is required when configuring the server with dual GPU cards If a GPU is installed in the full height PCIe riser cage option connect the GPU cable to the riser cage connector and the installed GPU CAUTION To prevent improper cooling and thermal damage do not operate the server unless all PCI slots have either an expansion slot cover or an expa...

Страница 75: ... GPUs are installed in the server Item Description 1 GPU 1 2 GPU 2 3 HPE Smart Array P440ar Controller Low profile PCIe slot riser cage option WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation ...

Страница 76: ... the access panel on page 22 5 Install the low profile riser cage HPE Smart Storage Battery To install the component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the acce...

Страница 77: ... cord to the power source 11 Power up the server Powering up the server on page 21 HPE Smart Array P440ar Controller option WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper ...

Страница 78: ...ack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Install the HPE Smart Array P440ar controller 6 Connect the SAS SATA cables to the backplane and Smart Array controller Install the SAS SATA cables according to their labels as Port 1 or Port 2 These labels are on the cables and their connections o 8SFF ...

Страница 79: ...lectrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove the primary PCI riser cage Remove the PCI riser cage...

Страница 80: ...ontroller board into slot 2 of the riser cage 8 Install the riser cage in the server Install the PCI riser cage on page 24 9 Connect the cables from port one and two on the backplane to port one on the P440 controller board If the H240 controller board is installed the SAS cables will use both ports o 8SFF ...

Страница 81: ... to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 ...

Страница 82: ...t Array P840 Controller board option WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 ...

Страница 83: ...n 83 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove the primary PCI riser cage Remove the PCI riser cage on page 23 6 Install the P840 controller board 7 Install the riser board assembly ...

Страница 84: ...ect the Mini SAS cables from the standard backplane to port one on the optional P840 controller board 9 If the 2SFF SAS SATA backplane is installed connect the Mini SAS cable from the optional backplane to port 2 on the P840 controller board ...

Страница 85: ...ts properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Disconnect the Power UID USB cable from the front power button USB 3 0 connec...

Страница 86: ...Hardware options installation 86 o 8SFF o 4LFF CAUTION When routing cables always be sure that the cables are not in a position where they can be pinched or crimped ...

Страница 87: ...s installation 87 To install the SID module 1 Guide the SID cable through the front of the server 2 Install the SID module into the front panel and secure the module to the chassis with the screws from the kit o 8SFF ...

Страница 88: ... allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the ra...

Страница 89: ...M PCIe blank 6 Install the component a Firmly seat the FlexibleLOM in the slot b Tighten the thumbscrew 7 Install the access panel on page 22 8 Slide the server into the rack 9 Connect the LAN segment cables 10 Connect each power cord to the server 11 Connect each power cord to the power source ...

Страница 90: ...o cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 R...

Страница 91: ...nal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the acce...

Страница 92: ...Hardware options installation 92 o Primary PCI riser cage o Secondary PCI riser cage ...

Страница 93: ...rly ground the server before beginning any installation procedure Improper grounding can cause ESD 1 Back up all server data 2 Power down the server on page 21 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the access panel on page 22 5 Remove the primary PCI riser cage Remove the PCI riser cage on page 23 6 Remove the e...

Страница 94: ...ard See the documentation that ships with the expansion board 9 Install the PCI riser cage on page 24 10 Install the access panel on page 22 11 Install the server into the rack 12 Connect each power cord to the server 13 Connect each power cord to the power source 14 Power up the server Powering up the server on page 21 Location discovery services ear option 1 Remove all power ...

Страница 95: ...Hardware options installation 95 a Disconnect each power cord from the power source b Disconnect each power cord from the server 2 Remove the access panel on page 22 ...

Страница 96: ...Hardware options installation 96 3 Remove the hot plug fan or fan blank from fan bay 1 ...

Страница 97: ...Hardware options installation 97 4 Remove the location discovery cable protection panel from the left side of the server ...

Страница 98: ...Hardware options installation 98 5 Remove the standard ear 6 Install the location discovery services ear option and route the location discovery services cable through side channel ...

Страница 99: ...Hardware options installation 99 7 Install the discovery cable protection panel 8 Connect the location discovery services cable to the location discovery services connector on the system board ...

Страница 100: ...e M 2 SSD Enablement Board 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Extend the server from the rack on page 21 4 Remove the access panel on page 22 5 Remove the PCIe riser cage Remove the PCI riser cage on page 23 6 Remove the expansion slot blank Removing the expansion slot blanks on pag...

Страница 101: ...er source 14 Power up the server Powering up the server on page 21 Installing an M 2 SSD Enablement Board The M 2 SSD enablement board is supported in either slot 1 or 2 of the Primary riser cage and slot 3 on the secondary PCI riser cage To install the component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord fr...

Страница 102: ...Hardware options installation 102 a Remove the full height bracket from the M 2 SSD enablement board b Install the low profile bracket on the M 2 SSD enablement board 7 Remove the expansion slot cover ...

Страница 103: ...e primary PCI riser or in slot 3 of the secondary PCI riser Be sure that the correct bracket is installed as directed earlier in this process 9 Connect and route the SATA cables from the M 2 SSD enablement board to the system board o M 2 SSD enablement board installed in slot 1 of the primary PCI riser ...

Страница 104: ...n This USB storage device connects to an internal USB connector and is configured upon boot To locate the internal USB connector see System board components on page 14 For more information see the Dual 8Gb microSD EM USB storage device documentation on the Hewlett Packard Enterprise website http www hpe com support 8GBDualMicrosd_ug_en 750 W Flex Slot Hot Plug Battery Backup Module The FSBBU is a ...

Страница 105: ...A 10 75W 6 25A No Yes Installing the FSBBU CAUTION To prevent improper cooling and thermal damage do not operate the chassis unless all bays are populated with a component or a blank To install the component 1 Access the product rear panel 2 Remove the blank WARNING To reduce the risk of personal injury from hot surfaces allow the FSBBU or power supply blank to cool before touching it 3 Press the ...

Страница 106: ...part number K9B28A is required for a daisy chain configuration 6 Charge the FSBBU module until the LED is solid green For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs Flex slot battery backup module LEDs and buttons Item Description 1 FSBBU module LED ...

Страница 107: ... see 750 W Flex Slot Hot Plug Battery Backup Module on page 104 Trusted Platform Module option For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs Use these instructions to install and enable a TPM on a supported server This procedure includes three sections...

Страница 108: ...ata access caused by improper TPM use For operating instructions see the encryption technology feature documentation provided by the operating system Installing the Trusted Platform Module board WARNING To reduce the risk of personal injury electric shock or damage to the equipment remove the power cord to remove power from the server Pressing the Power On Standby button does not shut off system p...

Страница 109: ... page 21 Retaining the recovery key password The recovery key password is generated during BitLocker setup and can be saved and printed after BitLocker is enabled When using BitLocker always retain the recovery key password The recovery key password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity To help ensure maximum security observe the follo...

Страница 110: ...he Enter key when prompted to reboot the server The server then reboots a second time without user input During this reboot the TPM setting becomes effective You can now enable TPM functionality in the OS such as Microsoft Windows BitLocker or measured boot CAUTION When a TPM is installed and enabled on the server data access is locked if you fail to follow the proper procedures for updating the s...

Страница 111: ... hardware options to optimize performance CAUTION When routing cables always be sure that the cables are not in a position where they can be pinched or crimped 2SFF embedded SATA backplane cabling 1 Connect the data cables to the SATA storage connector the SATA optical storage drive connector and the backplane presence detect connector ...

Страница 112: ...ill vary if a PCIe storage controller is installed 4LFF Universal Media Bay cabling Route the cables along the edge of the system board and then connect the cables to the system board 4LFF VGA USB connections Connect the VGA USB cable to the front VGA USB connector toward the rear of the system board 4LFF optical drive connection ...

Страница 113: ...te the cables along the edge of the system board and then connect the cables to the system board 8SFF DVD RW VGA USB connections o Connect the VGA USB cable to the front VGA USB connector toward the rear of the system board o Connect the SATA optical cable to the SATA optical storage drive connector 8SFF VGA USB connections ...

Страница 114: ...t Option cabling The Smart Array P440ar Controller is shown in the cabling diagram but other controllers may be supported For a list of supported controllers see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs Item Description 1 Connect the power cable from the 10SFF Express Bay backplane to the system board ...

Страница 115: ...y backplane to Port 3 on the HPE Express Bay Bridge Card 5 6 Connect the 10SFF Express bay data cable from 10SFF Express Bay backplane to Ports 1 and 2 on the HPE Express Bay Bridge Card If the 2SFF Express Bay Enablement option is not installed then this cable is not required HPE Smart Array P440ar controller cabling Connect the SAS SATA cables to the backplane and Smart Array controller Install ...

Страница 116: ...PE Smart Array P440 Controller cabling Connect the cables from port one and two on the backplane to port one on the P440 controller board If the H240 controller board is installed the SAS cables will use both ports 8SFF ...

Страница 117: ...HPE Smart Array P840ar controller cabling 1 Connect both the Mini SAS connectors from the 8SFF backplane to controller port 1 2 If the optional 2SFF backplane is installed connect the Mini SAS cable to controller port 2 ...

Страница 118: ...ng 1 Connect the Mini SAS cables from the standard backplane to port one on the optional P840 controller board 2 If the 2SFF SAS SATA backplane is installed connect the Mini SAS cable from the optional backplane to port 2 on the P840 controller board ...

Страница 119: ...sconnect all power cords to completely remove power from the server Connect the SATA cables from the backplane to the Mini SAS SATA connectors on the system board according to their labels as Port 1 or Port 2 These labels are on the cables and their connections 8SFF 4LFF Connect the SATA cable from port one on the backplane to port one on the system board as indicated on the connectors ...

Страница 120: ...nt Board option cabling The M 2 SSD enablement board option is supported in both the primary and the secondary PCI riser cage Cable the option according to the location in the server Primary PCI riser cage Secondary PCI riser cage ...

Страница 121: ...e FWUPDATE utility on page 130 Offline Product QuickSpecs For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info qs HPE iLO iLO is a remote server management processor embedded on the system boards of HPE ProLiant and Synergy servers iLO enables the monitoring and...

Страница 122: ...t log activities for example content created or passed through the operating system Active Health System log The data collected by the Active Health System is stored in the Active Health System Log The data is logged securely isolated from the operating system and separate from customer data When the Active Health System Log is full new data overwrites the oldest data in the log It takes less than...

Страница 123: ...rovides installation help for Microsoft Windows Red Hat and SUSE Linux and VMware operating systems For specific OS support see the Intelligent Provisioning Release Notes on the Hewlett Packard Enterprise website http www hpe com info intelligentprovisioning docs Intelligent Provisioning provides maintenance related tasks using the Perform Maintenance window For more information about Intelligent ...

Страница 124: ...lligent Provisioning User Guide Use the Erase Utility to erase drives and Active Health System logs and to reset UEFI System Utilities settings Run the Erase Utility if you must erase the system for the following reasons You want to install a new operating system on a server with an existing operating system You encounter an error when completing the steps of a factory installed operating system i...

Страница 125: ...ine scriptable interface The interfaces allow you to deploy firmware drivers and software for supported nodes For more information about SUM see the product page on the Hewlett Packard Enterprise website http www hpe com servers hpsum To download SUM see the Hewlett Packard Enterprise website http www hpe com servers hpsum download To access the Smart Update Manager User Guide see the Hewlett Pack...

Страница 126: ...nsion For example adding an OS boot loader or other UEFI application as a new UEFI boot option The new boot option is appended to the boot order list When you select a file you are prompted to enter the boot option description This description and any optional data to be passed to an EFI application is then displayed in the boot menu Boot to System Utilities After pre POST the boot options screen ...

Страница 127: ...r server on the Hewlett Packard Enterprise website http www hpe com info UEFI docs A physically present user can customize the certificates embedded in the UEFI BIOS by adding or removing their own certificates When Secure Boot is enabled the System Maintenance Switch does not restore all manufacturing defaults when set to the ON position For security reasons the following are not restored to defa...

Страница 128: ...guration RBSU Advanced Options Advanced System ROM Options Serial Number and then press the Enter key 3 Enter the serial number and press the Enter key The following message appears The serial number should only be modified by qualified service personnel This value should always match the serial number located on the chassis 4 To clear the warning press the Enter key 5 Enter the serial number and ...

Страница 129: ...ed with all devices in Legacy BIOS Boot Mode but are not available at USB 3 0 speeds in the preboot environment Standard USB support USB support from within the operating system is provided by the OS through the appropriate USB device drivers Support for USB 3 0 varies by operating system For maximum compatibility of USB 3 0 devices with all operating systems Hewlett Packard Enterprise provides a ...

Страница 130: ...ware or System ROM Service Pack for ProLiant on page 125 FWUPDATE utility on page 130 FWUpdate command from within the Embedded UEFI shell on page 131 Firmware Update application in UEFI System Utilities Firmware Update application in the UEFI System Utilities on page 131 Online Flash components on page 132 Product entitlement is required to perform updates For more information see Accessing updat...

Страница 131: ...Binary component for your server Enter one of the fsx file systems available such as fs0 or fs1 and press the Enter key 7 Use the cd command to change from the current directory to the directory that contains the binary file 8 Enter the fwupdate d BIOS f filename command to flash the system ROM For help on the FWUPDATE command enter the following command help fwupdate b 9 Reboot the server A reboo...

Страница 132: ... be sure that you are using the latest SPP version that your server supports To verify that your server is using the latest supported version and for more information about SPP see the Hewlett Packard Enterprise website http www hpe com servers spp download To locate the drivers for a particular server go to the Hewlett Packard Enterprise Support Center website http www hpe com support hpesc Under...

Страница 133: ... Services deliver confidence reduces risk and helps customers realize agility and stability We help customers succeed through Hybrid IT by simplifying and enriching the on premise experience informed by public cloud qualities and attributes HPE Support Services enables you to choose the right service level length of coverage and response time to fit your business needs Connect to HPE to help preve...

Страница 134: ... Let us know what Hewlett Packard Enterprise commercial products you own and we will send you the latest updates to keep your business running smoothly For more information see the Hewlett Packard Enterprise website http www hpe com info pcn ...

Страница 135: ...e courses of action for fault isolation and identification issue resolution and software maintenance on ProLiant servers and server blades The Troubleshooting Guide Volume II Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades To access the troubleshooting resources see the Hewlett Packard E...

Страница 136: ...tacts or dispose of in fire or water Replace only with the spare designated for this product To remove the component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Do one of the following o Extend the server from the rack on page 21 o Remove the server from the rack on page 22 4 Remove the acce...

Страница 137: ...ng Warranties Regulatory information Safety and regulatory compliance For important safety environmental and regulatory information see Safety and Compliance Information for Server Storage Power Networking and Rack Products available at the Hewlett Packard Enterprise website http www hpe com support Safety Compliance EnterpriseProducts Belarus Kazakhstan Russia marking Manufacturer and Local Repre...

Страница 138: ...clude YWW where Y indicates the year counting from within each new decade with 2000 as the starting point for example 238 2 for 2002 and 38 for the week of September 9 In addition 2010 is indicated by 0 2011 by 1 2012 by 2 2013 by 3 and so forth YYWW where YY indicates the year using a base year of 2000 for example 0238 02 for 2002 and 38 for the week of September 9 Turkey RoHS material content de...

Страница 139: ...ic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance i...

Страница 140: ...tions the supported system inlet temperature range is extended 5 C to 10 C 41 F to 50 F and 35 C to 40 C 95 F to 104 F at sea level with an altitude derating of 1 0 C per every 175 m 1 8 F per every 574 ft above 900 m 2953 ft to a maximum of 3048 m 10 000 ft 40 C to 45 C 104 F to 113 F at sea level with an altitude derating of 1 0 C per every 125 m 1 8 F per every 410 ft above 900 m 2953 ft to a m...

Страница 141: ... Supply on page 143 HPE 1400W Flex Slot Platinum Plus Hot plug Power Supply on page 144 For detailed power supply specifications see the QuickSpecs on the Hewlett Packard Enterprise website http www hpe com info proliant powersupply HPE 500W Flex Slot Platinum Hot plug Power Supply Specification Value Input requirements Rated input voltage 100 to 127 VAC 200 to 240 VAC 240 VDC for China only Rated...

Страница 142: ...ina only Power supply output Rated steady state power 800 W at 100 VAC to 127 VAC input 800 W at 200 VAC to 240 VAC input 800 W at 240 VDC input for China only Maximum peak power 800 W at 100 VAC to 127 VAC input 800 W at 200 VAC to 240 VAC input 800 W at 240 VDC input for China only HPE 800W Flex Slot Titanium Plus Hot plug Power Supply Specification Value Input requirements Rated input voltage 2...

Страница 143: ... at 277 VAC 874 W at 380 VDC BTUs per hour 3071 at 200 VAC 3026 at 277 VAC 2982 at 380 VDC Power supply output Rated steady state power 800 W at 200 VAC to 277 VAC input 800 W at 380 VDC input Maximum peak power 800 W at 200 VAC to 277 VAC input 800 W at 380 VDC input HPE 800W Flex Slot 48VDC Hot plug Power Supply Specification Value Input requirements Rated input voltage 40 VDC to 72 VDC 48 VDC n...

Страница 144: ...ing electrode conductor is connected This equipment must be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system must be earthed elsewhere The DC supply source is to be located within the same premi...

Страница 145: ...g power supply calculations For hot plug power supply specifications and calculators to determine electrical and heat loading for the server see the Hewlett Packard Enterprise Power Advisor website http www hpe com info poweradvisor online ...

Страница 146: ...cumentation to identify the recommended software update method To download product updates go to either of the following o Hewlett Packard Enterprise Support Center Get connected with updates page http www hpe com support e updates o Software Depot website http www hpe com support softwaredepot To view and update your entitlements and to link your contracts and warranties with your profile go to t...

Страница 147: ...hat an authorized service provider replace the part These parts are identified as No in the Illustrated Parts Catalog Based on availability and where geography permits CSR parts will be shipped for next business day delivery Same day or four hour delivery may be offered at an additional charge where geography permits If assistance is required you can call the Hewlett Packard Enterprise Support Cen...

Страница 148: ...rd consultez le site Web Hewlett Packard Enterprise http www hpe com support selfrepair Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose i prodotti Hewlett Packard Enterprise sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente CSR Customer Self Repair Se in fas...

Страница 149: ...nzeichnet CSR Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar Wenn Sie Hilfe benötigen können Sie das Hewlett Packard Enterprise Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen Den Materialien von ...

Страница 150: ...á cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio Para obtener más información acerca del programa de Reparaciones del propio cliente de Hewlett Packard Enterprise póngase en contacto con su proveedor de servicios local Si está interesado en el programa para Norteamérica visite la página web de Hewlett Packard En...

Страница 151: ... obra do serviço Opcional Peças cujo reparo feito pelo cliente é opcional Essas peças também são projetadas para o reparo feito pelo cliente No entanto se desejar que a Hewlett Packard Enterprise as substitua pode haver ou não a cobrança de taxa adicional dependendo do tipo de serviço de garantia destinado ao produto OBSERVAÇÃO Algumas peças da Hewlett Packard Enterprise não são projetadas para o ...

Страница 152: ...Support and other resources 152 ...

Страница 153: ...Support and other resources 153 ...

Страница 154: ...oduct includes additional remote support details use search to locate that information Remote support and Proactive Care information HPE Get Connected http www hpe com services getconnected HPE Proactive Care services http www hpe com services proactivecare HPE Proactive Care service Supported products list http www hpe com services proactivecaresupportedproducts HPE Proactive Care advanced servic...

Страница 155: ...application program interface ASHRAE American Society of Heating Refrigerating and Air Conditioning Engineers ASR Automatic Server Recovery CAS column address strobe CSA Canadian Standards Association CSR Customer Self Repair ESD electrostatic discharge FLR FlexibleLOM for rack servers FSBBU Flex slot battery backup GPU graphics processing unit ...

Страница 156: ...ights Out IML Integrated Management Log ISO International Organization for Standardization JSON JavaScript Object Notation LFF large form factor LRDIMM load reduced dual in line memory module NAND Not AND NMI nonmaskable interrupt NVDIMM non volatile dual in line memory module NVDIMM N non volatile dual in line memory module with byte addressable interface to DRAM NVRAM nonvolatile memory ...

Страница 157: ...OST Power On Self Test RBSU ROM Based Setup Utility RDIMM registered dual in line memory module RDP Rapid Deployment Pack REST representational state transfer RoHS Restriction of Hazardous Substances RSOC relative state of charge SAS serial attached SCSI SATA serial ATA SD Secure Digital SFF small form factor SID Systems Insight Display ...

Страница 158: ...ing Toolkit SUM Smart Update Manager TMRA recommended ambient operating temperature TPM Trusted Platform Module UEFI Unified Extensible Firmware Interface UID unit identification USB universal serial bus VCA Version Control Agent VCRM Version Control Repository Manager VDC voltage direct current ...

Страница 159: ...tion send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hpe com When submitting your feedback include the document title part number edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices page ...

Страница 160: ...of Conformity 137 138 default settings 48 device numbers 17 diagnostic tools 121 123 126 127 129 diagnostics utility 123 DIMM installation guidelines 45 46 DIMM population guidelines 48 49 DIMM slot locations 16 DIMM installing 51 DIMMs 45 46 51 DIMMs octal rank 45 DIMMs quad rank 45 DIMMs single and dual rank 45 downloading files 146 drive bay numbering 17 drive bays 7 17 drive cage assembly 57 5...

Страница 161: ... 137 L LED FSBBU module 106 LED unit identification UID 13 LEDs 11 LEDs troubleshooting 135 M M 2 SSD cabling 120 M 2 SSD enablement board 100 101 M 2 SSD enablement option 100 120 M 2 SSD module 100 maintenance guidelines 130 memory 41 45 46 48 49 memory configurations 47 48 memory subsystem architecture 45 memory Advanced ECC 48 memory configuration requirements 47 49 memory online spare 48 49 m...

Страница 162: ...40 static electricity 139 support 146 supported operating systems 132 133 supported targets 135 system battery 136 system board components 14 system components 7 system configuration settings 15 130 System Erase Utility 124 system maintenance switch 15 system power LED 8 system keeping current 130 Systems Insight Display 11 85 Systems Insight Display LEDs 10 11 T Taiwan battery recycling notice 13...

Отзывы: