Appendix B – Printed form for user defined parameter settings (remote operator)
B-3
Standard setting
Func.
No.
Function (Function mode)
Display
-FE -FU
S e t v a l u e
F-00 Base
frequency
F-BASE 050Hz
50Hz 60Hz
F-01 Maximum
frequency
F-MAX 050Hz
50Hz 60Hz
F-02 Start
frequency
Fmin 0.5Hz
0.5Hz 0.5Hz
Motor voltage for AVR function
AVR AC
200V
230/400V 230/460V
F-03
AVR function characteristic
AVR MODE
DOFF
DOFF DOFF
F-04 Voltage/frequency
characteristic
CONTROL VC
VC VC
1. Acceleration time
ACC1 0010.0s
10.0s 10.0s
Method to switch over
from 1. to 2. accel/decel time
ACC CHG
TM
TM TM
2. Acceleration
ACC2 0015.0s
15.00s 15.00s
Accel.1 / Accel.2
switchover frequency
ACC CHFr
000.0Hz
0.0Hz 0.0Hz
F-06
Acceleration characteristic
ACC LINE
L
L L
1. Deceleration time
DEC1 0010.0s
10.0s 10.0s
2. Deceleration time
DEC2 0015.0s
15.0s 15.0s
Decel.1 / Decel.2
switchover frequency
DEC CHFr
000.0Hz
0.0Hz 0.0Hz
F-07
Deceleration characteristic
DEC LINE
L
L L
F-10 Operation method after FRS cancelled
RUN FRS
ZST
ZST ZST
1. Multistage frequency setting
SPD 1
005.0Hz
0Hz 0Hz
2. Multistage frequency setting
SPD 2
005.0Hz
0Hz 0Hz
3. Multistage frequency setting
SPD 3
005.0Hz
0Hz 0Hz
4. Multistage frequency setting
SPD 4
005.0Hz
0Hz 0Hz
5. Multistage frequency setting
SPD 5
005.0Hz
0Hz 0Hz
6. Multistage frequency setting
SPD 6
005.0Hz
0Hz 0Hz
7. Multistage frequency setting
SPD 7
005.0Hz
0Hz 0Hz
8. Multistage frequency setting
SPD 8
005.0Hz
0Hz 0Hz
9. Multistage frequency setting
SPD 9
005.0Hz
0Hz 0Hz
10. Multistage frequency setting
SPD10 005.0Hz
0Hz 0Hz
11. Multistage frequency setting
SPD11 005.0Hz
0Hz 0Hz
12. Multistage frequency setting
SPD12 005.0Hz
0Hz 0Hz
13. Multistage frequency setting
SPD13 005.0Hz
0Hz 0Hz
14. Multistage frequency setting
SPD14 005.0Hz
0Hz 0Hz
F-11
15. Multistage frequency setting
SPD15 005.0Hz
0Hz 0Hz
DC brake active / not active
DCB SW
OFF
OFF OFF
DC brake frequency
DCB F
00.5Hz
0.5Hz 0.5Hz
DC brake waiting time
DCB WAIT
0.0s
0.0s 0.0s
DC brake braking torque
DCB V
000
0 0
F-20
DC brake braking time
DCB T
00.0s
0.0s 0.0s
Allowable undervoltage failure time
IPS UVTIME
01.0s
1.0s 1.0s
Waiting time until retry
IPS WAIT
010.0s
1.0s 1.0s
F-22
Restart mode
IPS POWR
ALM
ALM ALM
Electronic thermal characteristic
E-THM CHAR
SUB
CRT CRT
F-23
Electronic thermal
protection current
E-THM LVL
16.50A
Rated
current
Rated
current
Overload limit current
OLOAD LVL 20.63A
Rated cur-
rent *1,25
Rated cur-
rent *1,25
Deceleration rate
OLOAD CONST 01.0
1.0 1.0
F-24
Overload limit characteristic
OLOAD MODE
ON
ON ON
F-25 Software
lock
mode
S-LOCK MD1
MD1 MD1