GS4000 Installation Guide Revision 4.00
520-10-026-30X
1-25
*
NOTE: For the high port-density NIF and the high port-density PSU-integrated NIF, the
NIF number given to them by the system when they are installed are those
indicated with “
*
1” in the figure above.
(3) Power supply modules quantity and installation positions
The GS4000 power supply redundancy is of the type “2+2”. The GS4000 requires two active
power supply modules and two standby power supply modules. For detailed information about
installation positions of power supply modules, see the table below.
Table 1.1-11 Installation positions of power supply modules
active
standby active standby
power supply
redundancy
power supply
POW0-0
POW1-0 POW0-1 POW1-1
NOT redundant
○
×
○
×
Type “2+2”
Redundant
○
○
○
○
*
NOTE: If only one power supply module is installed, GS4000 will not become active even
after the GS4000 is powered on.
(4) LEDs (Light Emitting Diode) and Switches
The LED of a chassis indicates the action status of a fan unit, BCU , PSU
and high port-
density PSU-integrated NIF.
The LED is attached to the fan, and the status indicated by the LED differs depending on the
type of a device or the position where the fan unit is installed.
As for the status indicated by the each LED of a chassis, see Table 1.1-12. Refer to the section
“1.3 Power Supply,” “1.4 Basic Control Module (BCU),” or “1.6 Network Interface Module (NIF)”
for the LED and switches of other components.
Содержание GR4000-160E1
Страница 1: ...Hitachi Gigabit Switch GS4000 Series Installation Guide Revision 4 00 ...
Страница 100: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 1 82 This page left intentionally blank ...
Страница 128: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 2 28 This page left intentionally blank ...
Страница 150: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 3 22 This page left intentionally blank ...
Страница 276: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 5 72 This page left intentionally blank ...