GS4000 Installation Guide Revision 4.00
520-10-026-30X
3-15
3.2.11 OC-192c POS Single-mode Optical Fiber Cable
(Core Diameter: 10
μ
m, SC Twin-Core Connector)
This is used for the connection with OC-192c POS interface.
The boundary with OC-192c POS is the connector on GS4000.
In case of using NP192-1S, the maximum transmission distance between the devices with an
optic fiber which core/clad diameter is 10/125
μ
m (wave length: 1310nm) is 2Km.
In case of using NP192-1S4, the maximum transmission distance between the devices with an
optic fiber which core/clad diameter is 10/125
μ
m (wave length: 1550nm) is 40Km.
Figure 3.2-12 shows the rough sketch of the cable, and Table 3.2-17/3.2-18 show the
specification of optic fiber interfaces.
Figure 3.2-12 OC-192c POS Single-mode Optical Fiber Cable (Core Diameter: 10
μ
m)
Table 3.2-17 Specification of OC-192c POS (Network Interface NP192-1S)
Item
Specification
Emission peak wavelength
1.290 - 1.330
μ
m
Optical output level (average)
-6 - -1 dBm
Optical input level (average)
-11 - -1 dBm
Transmission loss
5 dB
Table 3.2-18 Specification of OC-192c POS (Network Interface NP192-1S4)
Item
Specification
Emission peak wavelength
1.530
~
1.565
μ
m
Optical output level (average)
-1 - +2 dBm
Optical input level (average)
-14 - -1 dBm
Transmission loss
13 dB
*
NOTE: The values shown in Table 3.2-17 and 3.2-18 comply with ITU-T G.691.
SC Twin-Core Connector
SC Twin-Core Connector
Содержание GR4000-160E1
Страница 1: ...Hitachi Gigabit Switch GS4000 Series Installation Guide Revision 4 00 ...
Страница 100: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 1 82 This page left intentionally blank ...
Страница 128: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 2 28 This page left intentionally blank ...
Страница 150: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 3 22 This page left intentionally blank ...
Страница 276: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 5 72 This page left intentionally blank ...