GS4000 Installation Guide Revision 4.00
520-10-026-30X
1-22
Table 1.1-10
LED Indicators on the GS4000-160E2 Chassis
Name Color
Role
Action
Status
FAN0
Shows the action status of FAN0.
FAN1
Green/Red
Shows the action status of FAN1.
Green (ON): running in normal condition
Red (ON): failure detected
BCU0
Shows the action status of BCU0.
BCU1
Green/
Yellow/
Red
Shows the action status of BCU1.
Green (ON): operation possible
Yellow (ON): locked out
Green (blinking): in preparation for startup
Red (ON): failure detected
OFF: BCU powered off (BCU
exchangeable)
PSU0 (NIF1/0)
Shows the action status of PSU0
(NOTE1)
PSU1 (NIF3/2)
Shows the action status of PSU1
(NOTE1)
PSU2 (NIF5/4)
Shows the action status of PSU2
(NOTE1)
PSU3 (NIF7/6)
Green/
Yellow/
Red
Shows the action status of PSU3
(NOTE1)
Green (ON): operation possible (NOTE2)
Green (blinking): in preparation for startup
Yellow (ON): locked out
Red (ON): failure detected
OFF: PSU powered off (PSU
exchangeable(NOTE3))
NOTE 1: When a high port-density PSU-integrated NIF is installed, its action status is shown here.
NOTE 2: When a high port-density PSU-integrated NIF is installed, and even though the LED status is “Green(blinking)”,
the NIF will not be active in the following cases:
・
During a time span of approximately 10 seconds after the LED status becomes “Green(ON)” after GS4000 is powered on.
・
The “close nif” command is entered from an operation terminal.
・
The “disable” configuration command is entered from an operation terminal.
NOTE 3: For a high port-density PSU-integrated NIF, the "OFF" status of LED means that exchanging the NIF is possible.
*
NOTE: Regarding the "close nif" command, see the manual " GS4000
・
GS3000 Software
manual, Operations Commands". As for the "disable" information, see the manual "
GS4000
・
GS3000 Software manual, Configuration Commands CLI -CLI Type 1
Hierarchical Input Format, Vol. 2.
(5) Accessories
No accessories provided.
NOTE: The rack mounting brackets of GS4000-160E2 are attached to its body
beforehand at the time of shipment.
*
NOTE: Do not install the optional components of GS4000 (or GR4000) into the devices
other than the GS4000 (or GR4000). Doing such a thing causes a fire or an
electric shock.
Содержание GR4000-160E1
Страница 1: ...Hitachi Gigabit Switch GS4000 Series Installation Guide Revision 4 00 ...
Страница 100: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 1 82 This page left intentionally blank ...
Страница 128: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 2 28 This page left intentionally blank ...
Страница 150: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 3 22 This page left intentionally blank ...
Страница 276: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 5 72 This page left intentionally blank ...