GS4000 Installation Guide Revision 4.00
520-10-026-30X
2-21
2.8 INSTALLATION
SPACE
The GS4000 can be installed on a table or mounted in a 19-inch rack (cabinet rack).
(1) Installation on a Desk or Table
Install the device on a flat and stable surface. Also, consider the following requirements when
setting the device on a table.
Table 2.8-1 Requirements for Setting the Device on a Table
Items
Requirements
Cooling condition
Reserve at least 70 mm of space from the ventilation slots of each device to ensure proper air flow
through the ventilation slots. (For details, see the section 2.10 Cooling Considerations.)
Space for placing
Cables
Reserve 100mm of space in front of and behind the device for placing cables.
Noise of the device
Regarding the noise, see the section 2.11 Device Noise.
WARNING: WHEN INSTALLING THE GS4000 OR GS4000 ON A DESK, LAY IT DOWN
HORIZONTALLY IN IT’S NORMAL ORIENTATION. IF YOU STAND IT VERTICALLY
OR LEAN IT AGAINST A WALL, IT COULD FALL AND BE DAMAGED AND
POTENTIALLY CAUSE INJURY.
(2) Installation in a 19-Inch Rack
The GS4000 can be mounted in the racks complying with the standard indicated in Table 2.8-
2.
Table 2.8-2 Rack Specification Required for GS4000 Models
Items
Requirements
Standard of racks
Use either of the following racks;
19-inch cabinet rack complying with EIA standard
Cooling conditions
Use a rack which allows you to secure at least 70mm of space between the pillars/side panels of a
rack and the ventilation slots of the device.
(For details, see the section 2.10 Cooling Considerations.)
Space for placing
Cables
Reserve 100mm of space in front of and behind the device for placing cables.
Table 2.8-3 Accessories/Tools Necessary for Mounting the Device into a Rack
Items
Requirements
Guide rails provided
with a rack
Should be sustainable to the weight of a device (See Table 2.2-1.)
Should not interfere with the rubber feet attached to the underside of a device (width: 45mm or
less) (See Figure 2.8-1.)
Should be installable in the position shown in the section 4.4, “Mounting the GS4000 in a Rack.”
Mounting screws
provided with a rack
Rack compliant with the EIA standard: M5 or M6 screws should be used.
(Regarding the required number of screws used to install the device into a rack, see Table 2.8-4.)
Содержание GR4000-160E1
Страница 1: ...Hitachi Gigabit Switch GS4000 Series Installation Guide Revision 4 00 ...
Страница 100: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 1 82 This page left intentionally blank ...
Страница 128: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 2 28 This page left intentionally blank ...
Страница 150: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 3 22 This page left intentionally blank ...
Страница 276: ...GS4000 Installation Guide Revision 4 00 520 10 026 30X 5 72 This page left intentionally blank ...