In this interface, you can set alarm linkage modes of the access host, including case trigger, event card interact, and client interact.
Case Trigger
Purpose:
The case (refer to the triggers of the controller) can be linked to some actions (e.g., alarm output, host buzzer) when it is triggered.
Steps:
1.
Click the
button to enter the case trigger interface, and select a case.
2.
Check the checkbox of the corresponding linkage actions and set the property as Trigger to enable this function.
Host Buzzer: The audible warning of controller will be triggered.
Reader Buzzer: The audible warning of card reader will be triggered.
Alarm Output: The alarm output will be triggered for notification.
Door (Open/Close): The door will be open or closed when the case is triggered.
3.
Click the Save button.
4.
Click the Apply button to take effect of the new settings.
Note:
The Door cannot be configured as open or closed at the same time.
Event Card Interact
In the Interact Configuration interface, click the Event Card Interact button to enter the settings interface.
Event Linkage
In the Event Interact interface, the linkage alarm action, after triggering alarm event, can be set. The alarm event can be divided into
four types: event device, event input alarm, door event, and card reader event.
Steps: