2. Wiring and connection
2-21
Emergency stop
ESTOP
39
In case of external emergency, it overrides all input
condition of the servo drive and quickly decelerates the
motor to free run the motor.
You can select the ON/OFF contact point in parameter
P02-26.
PI/P control
PI/P
41
It selects the type of speed controller.
(OFF:PI control ON:P control)
Stop/Start
STOP
13
It starts or stops the motor operation.
You can select the ON/OFF contact point in parameter
P02-25.
※
When setting P02-25 to “OFF”
(Close: Stop Open: Start)
♥ For details on the input contact point function change, refer to the P07 mode of Chapter 3.
2.5.4. Output signal function table (manufactured default)
Signal content
Name
Pin
number
Function and usage explanation
-
-
23
You can directly set the input contact point function
from P7-01. (Manufactured default : Not use)
Brake
operation
BRAKE
48
This is the output signal to operate the external
brake.
When on, the brake power is supplied to enable
motor operation.
Servo ready
RDY
21
No alarm, power good condition when the power is
on.
Speed/Position
/Torque reach
completion
INSPD/INP
OS/INTRQ
22
It goes on when it reaches the commanded
Speed/Position/Torque.
Speed/torque
limiting
SPDOUT/
TRQOUT
46
When used for speed control mode, it indicates the
condition of the torque the servo motor is limiting.
When used for torque control mode, it indicates the
condition of the speed the servo motor is limiting.
Zero speed
condition
ZSPD
47
This indicates the stopped condition of the servo
motor.
Alarm
condition
ALARM
20
When the alarm is detected, it goes off. During
normal operation, it goes on.
Alarm 0 CODE A_CODE0
45
It outputs alarm CODE0.
Alarm 1 CODE A_CODE1
19
It outputs alarm CODE1.
Alarm 2 CODE A_CODE2
44
It outputs alarm CODE2.
♥ For details on the output contact point function change, refer to the P08 mode of Chapter 3.
Содержание FDA7000 Series
Страница 42: ...1 Model check and handling 1 35...
Страница 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Страница 130: ...3 Parameter setting 3 51...
Страница 167: ...5 Servo operating 5 10...
Страница 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Страница 189: ...8 External view 8 3 External view D External view E...
Страница 190: ...8 External view 8 4 External view F External view G...
Страница 192: ...8 External view 8 6 External view I External view J...
Страница 193: ...8 External view 8 7 External view K External view L...
Страница 194: ...8 External view 8 8 External view M...
Страница 195: ...8 External view 8 9...