2. Wiring and connection
2-7
※
For the wiring of small/medium capacity socket, execute in the following order.
ⓐ
After checking the wire thickness indicated in 2.2.1, remove the wire coating.
- The coating of the wire to be used should be 8 ~ 9mm or less.
- The thickness of the wire permitted by the socket is as follows.
Wire type
Permitted wire thickness
Single wire
0.5 ~
0.8[mm]
Twisted wire
AWG28 ~ AWG12
ⓑ
Even though you can use the wire as is after removing the coating, for safety purposes put a
ferrule end to press with the crimping tool for ferrules insulated.
ⓒ
Open the terminal (plug) wire inserting hole with the lever as shown in the following picture.
ⓓ
Insert the core part of the wire to the opening part. Release the lever after inserting the wire.
ⓔ
Lightly pull it out to see whether there is any problem in the connected condition of the socket
and the wire.
ⓕ
When the coating of the wire is not completely inserted, it can cause electric shock.
Therefore check whether there are any exposed core wires.
Insulated Ferrule
Wire
Socket
Lever
Содержание FDA7000 Series
Страница 42: ...1 Model check and handling 1 35...
Страница 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Страница 130: ...3 Parameter setting 3 51...
Страница 167: ...5 Servo operating 5 10...
Страница 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Страница 189: ...8 External view 8 3 External view D External view E...
Страница 190: ...8 External view 8 4 External view F External view G...
Страница 192: ...8 External view 8 6 External view I External view J...
Страница 193: ...8 External view 8 7 External view K External view L...
Страница 194: ...8 External view 8 8 External view M...
Страница 195: ...8 External view 8 9...