3. Parameter setting
3-24
P03-16*
-10[V] RPM
Unit
rpm
Setting range
-9999.9 ~ 0.0
Manufactured
default
-Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the -10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-16)
Voltage
P03-17
Auto Offset
Unit
-
Setting range
ON / OFF
Manufactured
default
OFF
Speed/Torque
control
It automatically adjusts the offset voltage of the servo drive for the analog 0 [V] input of the host
controller. At first, servo off and then supply the zero speed voltage to the speed input pin of CN1
connector. And then set P03-17 on and adjust the offset voltage automatically so that it can
detect the connected voltage to zero speed. When the offset voltage adjustment is complete, the
P03-17 is automatically turned off and the offset voltage is automatically updated to the
parameter of P03-18.
P03-18
Manual Offset
Unit
mV
Setting range
-1000.0 ~ 1000.0
Manufactured
default
0.0
Speed/Torque
control
P03-19*
Override ENB
Unit
-
Setting range
ON / OFF
Manufactured
default
OFF
Speed control
The override mode operation is set to ON when minute speed is adjusted when the user is
combining the speed command with the speed by digital contact point or analog speed command.
Содержание FDA7000 Series
Страница 42: ...1 Model check and handling 1 35...
Страница 57: ...2 Wiring and connection 2 14 Drawing C Order Code Please contact our sales office...
Страница 130: ...3 Parameter setting 3 51...
Страница 167: ...5 Servo operating 5 10...
Страница 188: ...8 External view 8 2 External view B CN1 CN3 CN2 External view C...
Страница 189: ...8 External view 8 3 External view D External view E...
Страница 190: ...8 External view 8 4 External view F External view G...
Страница 192: ...8 External view 8 6 External view I External view J...
Страница 193: ...8 External view 8 7 External view K External view L...
Страница 194: ...8 External view 8 8 External view M...
Страница 195: ...8 External view 8 9...