Model PFE- 591
SCHEDULE
m. If “4,SCHED” is selected, “SP-8A” shows in the display, and
followed by “SCHEDULE”. Press the and up
to 4 different times of day can be programmed, by pressing
.
.
EX:
SP-8A “SCHEDULE” F1: 10.00A
SP-8B “SCHEDULE” F2: 2.00P
SP-8C “SCHEDULE” F3: 8.00P
SP-8D “SCHEDULE” F4: - - - -
Unneeded times should be left at “- - - -”, otherwise,
“Filter Suggested” shows in the display, prompting the
operator to start filtering.
Cooking is still permitted during the “suggested” phase.
However, if lockout is enabled, and the fryer still has
not been filtered after one hour, then the controller activates
lockout mode and prompts “FILTER
LOCKOUT – YOU
*MUST* FILTER NOW”.
n. Press and “SP-8E” “SKIP IF
LESS THAN...” shows in the display, followed by the
number of loads between filters, ex: “LOAD 4”. In
this example, if the suggested filter time occurs, before
4 loads have been cooked, then the filter operation is
skipped. If more than 4 loads have been cooked, then
“Filter Suggested” shows in the display. The numbers
of loads can be set by pressing .
o. Press and “SP-8F” shows in the display, followed by
“LOCKOUT ENABLED?” Press
to choose
“YES” or “NO”.
p. Press and “SP-8G” shows in the display followed by
SP-8G “LOCKOUT - HEAT OIL...” and a shortening
temperature, when reached, allows the operator to filter.
Example, “LOCKOUT - HEAT OIL... 300F” means the
display shows “FILTER LOCKOUT” “WAIT”, until 300F is
reached, then display shows “FILTER LOCKOUT”/”YOU
*MUST* FILTER NOW”, and repeated high-low tones
are activated. This prompts the user that it is now time
to filter the shortening. Press to change.
3-16. SPECIAL PROGRAM
MODE (Continued)
3-40
1005
Содержание PFE-591
Страница 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Страница 2: ......
Страница 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Страница 11: ...Model PFE 591 404 2 4...
Страница 16: ......
Страница 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Страница 65: ......