Model PFE- 591
3-9. FILTERING INSTRUCTIONS
7.
Turn COOK/PUMP switch to PUMP.
(Continued)
8.
When all shortening has been pumped into frypot turn
COOK/PUMP switch off.
IF THERE ARE AIR BUBBLES COMING UP IN THE
SHORTENING, IT’S POSSIBLE THAT THE FILTER
CONNECTION AT THE UNION ON THE FILTER
TUBE IS NOT TIGHTENED PROPERLY. IF SO,
TURN OFF THE PUMP AND USE PROTECTIVE
CLOTH OR GLOVE WHEN TIGHTENING THE
UNION. THIS UNION WILL BE HOT AND SEVERE
BURNS COULD RESULT.
3-10. CHANGING THE FILTER
The filter envelope should be changed after 10-12 filterings, or
ENVELOPE
whenever it becomes clogged with crumbs. Proceed as follows:
1.
Move the COOK/PUMP switch to the OFF position.
2.
Remove and empty the condensation drain pan.
3.
Disconnect the filter union and remove the filter drain pan
from beneath the frypot.
Use protective cloth or glove when disconnecting the
filter union or severe burns could result.
If the filter pan is moved while full of shortening, use
care to prevent splashing, or severe burns could result.
4.
Lift the filter screen assembly from the drain pan.
5.
Wipe the shortening and crumbs from the filter drain pan.
Clean the filter drain pan with soap and water. Thoroughly
rinse with hot water.
6.
Unthread the standpipe from the filter screen assembly.
7.
Remove the crumb catcher and clean thoroughly with
hot water.
3-20
703
Содержание PFE-591
Страница 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Страница 2: ......
Страница 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Страница 11: ...Model PFE 591 404 2 4...
Страница 16: ......
Страница 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Страница 65: ......