Model PFE- 591
3-16. SPECIAL PROGRAM
The Special Program Mode is used to set more detailed
MODE
parameters listed below.
SP-1
· Degrees Fahrenheit or Celsius
SP-2
· Language: English, French, German,
Spanish, and Portuguese
SP-3
· System initialization
SP-4
· Audio volume
SP-5
· Audio tone
SP-6
· Type of shortening to be melted - liquid, solid
SP-7
· Idle Mode
SP-8
· Filter tracking
SP-9
· Product buttons
SP-10
· Clean-out minutes
SP-11
· Clean-out temperature
SP-12
· Nominal amps reading
SP-13
· Amps reading low limit (percentage)
SP-14
· Amps reading high limit (percentage)
SP-15
· Program code change
SP-16
· Usage code change
SP-17
· Change shortening - A-Cook Cycles
SP-18
· Change shortening - B-Hours
1.
Press and hold for 5 seconds until
“L-2” and “LEVEL 2”, followed by, “SP PROG” and
“ENTER CODE shows in the display.
2.
Enter code 1, 2, 3, and “SP- 1 “, “TEMP, UNITS”
shows in the display.
If a bad code is entered, an alarm sounds and “BAD
CODE” shows on the display. Wait a few seconds,
the control reverts back to the Cook Mode, and
repeat the above steps.
To exit from the Special Program Mode at any time, press
and hold button for 2 seconds, or to roll back to
previous setting, press
.
Degrees Fahrenheit or Celsius (SP-1)
a. Follow steps 1 and 2 above.
b. The display flashes “SP- 1” and “TEMP, UNITS”, along
with “ºF” or “ºC”. Press
buttons to toggle from “ºF” to “ºC”, or vice versa.
1005
3-35
Содержание PFE-591
Страница 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Страница 2: ......
Страница 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Страница 11: ...Model PFE 591 404 2 4...
Страница 16: ......
Страница 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Страница 65: ......