OPERATION
6
83
Senator S24S
01/2019 - Senator S24S Radar Manual v1.00 en
B2.11
Ullage Volume
This menu item shows the ullage
volume readings measured at this
time. This measurement data is shown
with the units set in menu C7.5 Units
C7.5 Units
C7.5 Units
C7.5 Units.
This menu item is only available if you
set up a conversion (volume) table in
menu item C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table.
Read only
—
B2.12
Ullage Mass
This menu item shows the ullage mass
readings measured at this time. This
measurement data is shown with the
units set in menu C7.5 Units
C7.5 Units
C7.5 Units
C7.5 Units. This
menu item is only available if you set
up a conversion (mass) table in menu
item C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table.
Read only
—
B2.13
Sensor Temp.
Temperature of the sensor electronics
block.
Read only
—
B2.14
Converter Temp.
Temperature of the converter
electronics block. Operation of display
can stop if the temperature is below
-20
°
C / -4
°
F or above +70
°
C / +158
°
F.
Read only
—
B3 Power Spectrum
B3.2
Power Spectrum
This menu item shows the raw spectra
data of the radar signal which makes a
reflection on the surface of the silo
contents and is received by the device.
This data is shown as a graph of the
percentage of the full-scale signal
against distance.
Read only
—
B4 Corrected Spectrum
B4.2
Corrected
Spectrum
This menu item shows the corrected
spectra data of the radar signal which
makes a reflection on the surface of
the silo contents and is received by the
device. This is the result of the spectra
data from an empty silo subtracted
from the power spectra data. This data
is shown as a graph of the percentage
of the full-scale signal against
distance.
Read only
—
B5 Empty Spectrum
B5.2
Empty Spectrum
This menu item shows the spectra of
the radar signal which makes a
reflection on objects inside an empty
tank (interference signals). This data is
shown as a graph of the percentage of
the full-scale signal against distance.
It is also possible to do an empty
spectrum scan in a partially full tank, if
it is not possible to remove all the tank
contents.
Read only
—
1
The default value is the measured value at the time that you start the simulation
Menu
No.
Function
Function description
Selection list
Default
www.hawkmeasurement.com