OPERATION
6
91
Senator S24S
01/2019 - Senator S24S Radar Manual v1.00 en
C5.1.4.3
Tertiary Var.
This is the third measurement type shown
on HART
®
controllers. Make a selection
from the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Level, Distance, Sensor
Value, Reflection
2
Reflection
C5.1.4.4
Quaternary Var. This is the fourth measurement type shown
on HART
®
controllers. Make a selection
from the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Level, Distance, Sensor
Value, Reflection
2
Sensor Value
C6 Display
C6.1
Language
Data can be shown in one of the languages
stored in the device. Make a selection from
the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
English, German,
French, Italian,
Portuguese, Spanish,
Czech, Polish, Chinese
(simplified), Japanese,
Russian, Turkish
English
C6.2
Backlight
If you set this menu item to "Enabled", a
light comes on when you push a button on
the display keypad and if the loop current is
more than 6 mA.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Disabled, Enabled
Enabled
C6.3
Contrast
The contrast control for the display screen.
You can select a shade of grey between
light grey (-10) and black (+10).
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
min-max:
-10...+10
0
C6.4 1st Meas. Page
C6.4 1st Meas. Page
C6.4 1st Meas. Page
C6.4 1st Meas. Page
C6.4.1
Function
This menu item changes the configuration
of data shown on the display screen in
Normal mode. There are two measurement
pages available to show readings in Normal
mode. This setting is for the first page.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
One Value, One Value &
Bar, Two Values, Two
Values & Bar, Three
Values
One Value &
Bar
C6.4.2
1st Value
Variable
This changes the measurement type of the
first value on the measurement page.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Level, Distance, Sensor
Value, Reflection
2
Distance
C6.4.3
0% Range
This is the 0% value given to the bar graph
indicator in Normal mode. The range is
related to the measurement type set in
C6.4.2 1st Value Variable. This menu item is
only available if you set C6.4.1 Function to
"One Value & Bar" or "Two Values & Bar".
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting:
setting:
setting: User
Refer to "Function
description".
Refer to
"Function
description".
Menu No. Function
Function description
Selection list
Default
www.hawkmeasurement.com