OPERATION
6
101
Senator S24S
01/2019 - Senator S24S Radar Manual v1.00 en
•
[
], [>>>>], [
] and 2 × [>
>>>].
•
[
] or [
] for the selection of the
empty spectrum type (Full
(Average), Full (Max), Partial
(Average), Partial (Max)).
•
[
^
^
^
^
] to confirm.
Push these buttons to start the Record
Spectrum (Empty Spectrum) procedure.
Empty spectrum type. Make a selection
from the list of parameters. If you can
empty the tank, set this menu item to "Full,
Average" or "Full, Max". If you cannot
empty the tank, set this menu item to
"Partial, Average" or "Partial, Max".
If you use air blowers to decrease the angle
of the product surface, set Empty Spectrum
Empty Spectrum
Empty Spectrum
Empty Spectrum
Type
Type
Type
Type to "Partial, Max".
•
[>>>>] to change the position of the
cursor.
•
[
] to decrease the value (or move
the decimal point one digit to the
left) or [
] to increase the value (or
move the decimal point one digit to
the right).
•
[
^
^
^
^
] to confirm.
Partial distance. If you set Empty Spectrum
Empty Spectrum
Empty Spectrum
Empty Spectrum
Type
Type
Type
Type to "Partial, Average" or "Partial, Max",
you will have one more step to do in this
procedure. You must give a "partial
distance" value less than or equal to the
distance to the product surface from the
flange facing or thread stop of the process
connection.
CAUTION!
CAUTION!
CAUTION!
CAUTION!
If the "partial distance" value is more than
the distance to the product surface, then
the device will filter the level signal and the
device will not measure the level of the
product correctly.
•
[
^
^
^
^
] to confirm.
Make sure that the tank is empty or it
contains not more than the minimum
quantity. Energize and operate all
equipment that moves in the silo.
•
[
] or [
] to change the parameter
("No" or "Yes").
•
[
^
^
^
^
] to confirm.
Start recording? Set this menu item to
"Yes" to continue to the subsequent step.
Set this menu item to "No" to go back to the
menu.
•
[
^
^
^
^
] to confirm.
Graph with the results of the empty
spectrum recording.
•
[
] or [
] to change the parameter
("No" or "Yes").
•
[
^
^
^
^
] to confirm.
Save spectrum? If you set the menu item to
"Yes", the device will keep this empty
spectrum recording. If you set the menu
item to "No", the device will reject this data.
Screen
Steps
Description
9
www.hawkmeasurement.com
Содержание Senator S24S
Страница 173: ...NOTES 11 173 Senator S24S 01 2019 Senator S24S Radar Manual v1 00 en www hawkmeasurement com...
Страница 174: ...11 NOTES 174 Senator S24S 01 2019 Senator S24S Radar Manual v1 00 en www hawkmeasurement com...
Страница 175: ...NOTES 11 175 Senator S24S 01 2019 Senator S24S Radar Manual v1 00 en www hawkmeasurement com...