![Hatz 3H50 Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/hatz/3h50-series/3h50-series_manual_2107433058.webp)
Transport, assembly and commissioning
3H50, 4H50
58
HATZ
Manual
3
Operating indicator
4
Charge control
5
Oil pressure indicator
Ignition lock
0
Off
I
Operation
II
Start
NOTICE
For further details on the instrument box, see section
Procedure
NOTICE
i
▪
Start for max. 20 seconds. If the engine is still not running
after that, turn the starting key back to position "0" and elimi-
nate the cause (see section
).
▪
Turn the starting key to position "0" every time you want to
start the engine. The starter protection module prevents the
starter from engaging while the engine is running and be-
coming damaged.
Step
Activity
Venting the fuel system
1
Insert the starting key all the way and turn to position "I".
Depending on the model, the following indicators light up:
▪ Pre-glow indicator (2)
▪ Charge control (4)
▪ Oil pressure indicator (5)
2
Leave the starting key at position "I" until you hear the electrical
fuel feed pump switch off (approx. 30 seconds).
3
Turn the starting key back to position "0".
Note:
Carry out steps 2 and 3 several times to press the air out of the
fuel system.