3H50, 4H50
Operation and use
HATZ
63
Manual
3
Operating indicator
4
Charge control
5
Oil pressure indicator
6
Engine temperature indicator
Ignition lock
0
Off
I
Operation
II
Start
NOTICE
For further details on the instrument box, see section
Procedure
NOTICE
i
▪
Start for max. 20 seconds. If the engine is still not running
after that, turn the starting key back to position "0" and elimi-
nate the cause (see section
).
▪
Turn the starting key to position "0" every time you want to
start the engine. The starter protection module prevents the
starter from engaging while the engine is running and be-
coming damaged.
Step
Activity
1
Insert the starting key all the way and turn to position "I".
Depending on the model, the following indicators light up:
▪ Pre-glow indicator (2)
▪ Charge control (4)
▪ Oil pressure indicator (5)
NOTE:
If the optional engine temperature indicator (6) lights up,
the coolant temperature is inadmissibly high. Do not start the
engine; eliminate the cause.
When the pre-glow indicator goes out, continue with step 2.
2
Turn the starting key to position "II".