2 Installation
14
9
8
5
12
4 Studio Warning Relay
Studio Warning Relay
Studio Dim Relay
Logic Ground
Logic Ground
Logic Ground
Relays Common
Studio Mute Relay
11
13
10
1
2
3
6
7
Int
ernal L
o
gic
Talk to Studio Relay
Logic 5VDC
Logic 5VDC
Studio Mute Input (-)
Studio Dim Input (-)
Enable Logic Inputs (+)
Notes:
Opto-Isolated inputs are current limited to work
with +5 to +40 VDC logic.
Opto-Isolated outputs can sink up to 60 volts or
350 mA max. current flow.
For fully isolated operation, do not connect external
devices to +5 or ground (pins 1, 2, 3, 6 and 7).
1 2 3 4 5 6 7
8 9 10 11 12 13 14
Wire insertion end view
1 - LOGIC GND
2 - LOGIC GND
3 - LOGIC GND
4 - WARNING RELAY
5 - WARNING RELAY
6 - +5 VOLT LOGIC SUPPLY
7 - +5 VOLT LOGIC SUPPLY
8 - MUTE STUDIO (-)
9 - DIM STUDIO (-)
10 - RELAYS COMMON
11 - MUTE RELAY
12 - DIM RELAY
13 - TALK TO STUDIO RELAY
14 - ENABLE LOGIC INPUTS (+)
Studio Logic Interface,
Connector Pinout and Block Diagram
Assignable Logic Interface,
Connector Pinout and
Block Diagram, default signals
4
2
9
3
11
MIC: On Tally Relay
LINE: Start Pulse Relay
Logic Ground
Tally & Pulse Common
6
1
12
10
7
Inter
nal Logic
Logic 5VDC
Logic 5VDC
Logic 5VDC
On (-)
Off (-)
MIC: Talk To C/R (-)
LINE: Cue (-)
Enable Logic Inputs (+)
Notes:
Opto-Isolated inputs are current limited to work
with +5 to +40 VDC logic.
Opto-Isolated outputs can sink up to 60 volts or
350 mA max. current flow.
For fully isolated operation, do not connect external
devices to +5 or ground (pins 1, 7, 10, and 12).
8
MIC: Cough (-)
LINE: Ready (-)
5
MIC: Off Tally Relay
LINE: Stop Pulse Relay
1 2 3 4 5 6
7 8 9 10 11 12
Wire insertion end view
1 - LOGIC GND
2 - TALK TO C/R / CUE (-)
3 - OFF (-)
4 - ENABLE LOGIC INPUTS (+)
5 - OFF TALLY / STOP PULSE
6 - TALLY & PULSE COMMON
7 - +5 VOLT LOGIC SUPPLY
8 - COUGH / READY (-)
9 - ON (-)
10 - +5 VOLT LOGIC SUPPLY
11 - ON TALLY / START PULSE
12 - +5 VOLT LOGIC SUPPLY
14
9
8
5
12
4 Control Room Warning Relay
Control Room Warning Relay
Control Room Dim Relay
Logic Ground
Logic Ground
Logic Ground
Relays Common
Control Room Mute Relay
11
13
10
1
2
3
6
7
Int
ernal L
o
gic
Talk to Control Room Relay
Logic 5VDC
Logic 5VDC
Ctrl Room Mute Input (-)
Ctrl Room Dim Input (-)
Enable Logic Inputs (+)
Notes:
Opto-Isolated inputs are current limited to work
with +5 to +40 VDC logic.
Opto-Isolated outputs can sink up to 60 volts or
350 mA max. current flow.
For fully isolated operation, do not connect external
devices to +5 or ground (pins 1, 2, 3, 6 and 7).
1 2 3 4 5 6 7
8 9 10 11 12 13 14
Wire insertion end view
1 - LOGIC GND
2 - LOGIC GND
3 - LOGIC GND
4 - WARNING RELAY
5 - WARNING RELAY
6 - +5 VOLT LOGIC SUPPLY
7 - +5 VOLT LOGIC SUPPLY
8 - MUTE C/R (-)
9 - DIM C/R (-)
10 - RELAYS COMMON
11 - MUTE RELAY
12 - DIM RELAY
13 - TALK TO C/R RELAY
14 - ENABLE LOGIC INPUTS (+)
Control Room Logic Interface,
Connector Pinout and Block Diagram
10
11
12
7
4 External Timer Reset
External Dim Relay
Logic Ground
Logic Ground
Relays Common
External Mute Relay
6
5
3
2
9
8
1
Int
ernal L
o
gic
Talk to External Relay
Logic 5VDC
Logic 5VDC
Ext Cue On Input (-)
Ext Talk to CR Input (-)
Enable Logic Inputs (+)
Notes:
Opto-Isolated inputs are current limited to work
with +5 to +40 VDC logic.
Opto-Isolated outputs can sink up to 60 volts or
350 mA max. current flow.
For fully isolated operation, do not connect external
devices to +5 or ground (pins 1, 2, 8, and 9).
1 2 3 4 5 6
7 8 9 10 11 12
Wire insertion end view
1 - +5 VOLT LOGIC SUPPLY
2 - LOGIC GND
3 - RELAYS COMMON
4 - TIMER RESET
5 - TALK TO EXT. RELAY
6 - EXTERNAL MUTE RELAY
7 - EXTERNAL DIM RELAY
8 - +5 VOLT LOGIC SUPPLY
9 - LOGIC GND
10 - ENABLE LOGIC INPUTS (+)
11 - EXT TALK TO C/R (-)
12 - REMOTE CUE (-)
Cue/Talk/External Logic Interface,
Connector Pinout and Block Diagram