Revision C • 10/07
H
A
R
R
I
S
C
O
R
P
O
R
A T
I
O
N
2-2
2 Installation
FRAME CONFIGURATION
Two panels are available for the RMX
digital:
the Universal Dual Fader Input and the Monitor
Control, which is standard on the mainframe. The
Dual Fader panel is two input slots wide, while
the Monitor Control panel is three slots wide. Typi-
cal panel positions are shown below, but panels
can be positioned up to two slots from their stan-
dard slot designations since each panel connects
to the mainframe using a single red CAT-5 cable.
Input slots can have any combination of Dual
Fader panels, single or dual width blank panels,
single or dual width divider kits, or custom switch/
control panels installed.
Contact a Harris sales representative for more
details on available RMX
digital options.
Console Installation
To simplify console installation, logic cable wir-
ing diagrams for specific peripheral equipment are
available from Harris Technical Support. Refer to
page 5-1 for contact information.
INSTALLATION NOTE:
Do not position the con-
sole near intense electromagnetic hum fields such
as those created by audio amplifiers that use in-
expensive power transformers operating in or near
saturation. Strong electromagnetic fields may im-
pair the performance of the RMX
digital and neigh-
boring equipment. Route audio cables to achieve
maximum practical distance from all AC power
mains wiring.
N O
N O
N O
N O
N OTE:
TE:
TE:
TE:
TE:
The number of available input slots equals the console
model number (e.g., RMXd-20 has 20 input slots). All RMXdigital
frames have one KSU card with DSP for the buses, four input
channels and four special purpose phantom channels. Each DSP
card adds the DSP for another eight input channels (e.g., RMXd-
4 has no DSP card, RMXd-12 has one DSP card, RMXd-20 has
two DSP cards, and RMXd-28 has three DSP cards).
The RMXd Divider Kit allows standard Harris/PR&E Turret
Accessory Panels to be installed in a frame. There are two kits
RMX
digital-12, Frame Configuration
99-1409 Single
Width Blank P
a
nel (standard
)
99-1406 Monitor C
o
nt
rol P
a
nel (one standard
)
with Se
ss
io
n
, Co
n
trol Ro
om
and Studio Monitor C
o
nt
ro
ls
The DSP, KSU and 8-Input Exp. cards are hidden below a card access cover.
* The number of DSP Cards installed is determined by the frame size.
** The 99-2672-1 KSU Card comes standard in all frame sizes.
Input Slot 1
Input Slot 2
Input Slot 3
Input Slot 4
Input Slot 5
Input Slot 6
Input Slot 7
Input Slot 8
Input Slot 9
Input Slot 10
Input Slot 11
Input Slot 12
99-1407 Universal Dual Fader panels
take up two input slots, so there can be
up to six in a 12-input slot mainframe.
Remaining input slots are covered with
99-1410 Dual Width Blank Panels.
99-2667 DSP Card *
99-2665 8-Input Expansion Card (optional)
99-2672-1 or 99-2672-2 KSU Card **
80-1846 Blank Panel
Input Slots:
available: 99-1411-1 is one input slot wide and holds one or
two single width turret panels; 99-1411-2 is two input slots wide
and holds two dual width panels, four single width panels, or a
combination thereof. A kit can be installed into any input slot
location. Dual Fader panels or the Monitor Control panel can be
moved left or right one or two slots to accommodate a divider kit.
Blank turret panels 99-1714-3 (1.6" x 6") or 99-1740-3 (3.2"
x 6") cover unused accessory panel openings when using the
divider kit.
Содержание RMXDIGITAL
Страница 2: ...Revision C 10 07 H A R R I S C O R P O R A T I O N ii...
Страница 90: ......