WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
indications can be supplied via J15 & J16 or can be supplied by an external voltage
source. The status output connections are listed in Table 2-2.
Table 2-2 J15 & J16, External I/O Board, Remote Status Outputs
Connector
Schematic Label
Status Output
J16-1
GNDB
Isolated Ground
J16-2
+5VDC_ISOLATED
Output - install jumper to J16-11 to use internal supply for status pull
ups. Otherwise an external supply will have to be connected to J16-11.
J16-3
/OUTPUT 1
Off/On Status
J16-4
/OUTPUT 2
Life Support Status
J16-5
/OUTPUT 3
RF Mute Status
J16-6
/OUTPUT 4
External Interlock Status
J16-7
/OUTPUT 5
Drive Chain Fault Status
J16-8
/OUTPUT 6
Power Amp Fault Status
J16-9
/OUTPUT 7
Output Fault Status
J16-10
/OUTPUT 8
Power Supply Fault Status
J16-11
+VDC_EXT_SUPPLY
Input For External Pull Up Supply Voltage
J16-12
GNDB
Isolated Ground
J15-1
GNDB
Isolated Ground
J15-2
+5VDC_ISOLATED
Output - install jumper to J15-11 to use internal supply for status pull
ups. Otherwise an external supply will have to be connected to J15-11.
J15-3
/OUTPUT 9
Control Fault Status
J15-4
/OUTPUT 10
Cooling Fault Status
J15-5
/OUTPUT 11
Summary Fault Status
J15-6
/OUTPUT 12
Remote Control Enabled Status
J15-7
/OUTPUT 13
Transmitter Off Status
J15-8
/OUTPUT 14
RF Switch A/B Status
J15-9
/OUTPUT 15
RF_SW_SEL_OUT (to motorized RF switch)
J15-10
/OUTPUT 16
VSWR Fault/Foldback Active Status
J15-11
+VDC_EXT_SUPPLY
Input For External Pull Up Supply Voltage
J15-12
GNDB
Isolated Ground
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...