12/24/07
888-2685-001
4-15
WARNING: Disconnect primary power prior to servicing.
Section 4 RF Testing
Ranger Commissioning Manual
4.2.13.4 Out of Band Emissions Procedure
Step
Procedure Description
Expected Observation
1
Configure the transmitter to operate
on air with Exciter A with
precorrector settings to:
Non-Linear Precorrection = ADAPT
Linear Precorrection = ADAPT
Then connect the spectrum analyzer
to the transmitter output of the
bandpass filter.
RF Spectrum output should be
clean.
2
Configure the spectrum analyzer as
follows:
Start Frequency = 698 MHz
Stop Frequency = 715.9 MHz
Resolution BW = 100 KHz
Video BW = 300 Hz
Sweep = Auto
Sweep Points = 10001(number of
points in sweep)
Amplitude Reference Level = 10 dB
Amplitude Attenuation = 30 dB
Then measure 698–715.9 MHz with
Exciter A on air.
Less than -38 dBm/100 kHz
3
Change the following spectrum
analyzer settings:
Start Frequency = 722.1 MHz
Stop Frequency = 746 MHz.
Then measure 722.1–746 MHz with
Exciter A on air.
Less than -38 dBm/100 kHz
4
Change the following spectrum
analyzer settings:
RBW = 30 Khz
Start Frequency = 715.9 MHz
Stop Frequency = 716 MHz.
Then measure 715.9-716 MHz with
Exciter A on air.
Less than -38 dBm/30 kHz
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...