4-10
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 4 RF Testing
4.2.11.4 Frequency Tolerance Procedure
NOTE:
The operating frequency of 719 MHz is for U.S. operation. Qualcomm may
define other UHF frequencies for international operation.
4.2.11.5 Frequency Tolerance Test Results
Step
Procedure Description
Expected Observation
1
Generate a CW tone as per the
instructions in Appendix B.
2
Using a frequency counter (or a
spectrum analyzer) measure the fre-
quency of the tone coming out of the
Exciter for 30 minutes (Provide the
frequency counter/spectrum ana-
lyzer with a reference signal derived
from the same GPS signal that the
Exciter has).
The maximum deviation of the car-
rier tone from 719000000 should be
less than ±1.0 Hz
3
Set FLO FPGA, SFN mode = Off.
Also, increase the SFN limit to 500
microseconds. Remove the 1PPS
signal, and using the frequency
counter/spectrum analyzer measure
the frequency of the tone overnight/
24 hours.
The maximum deviation of the car-
rier tone from 719000000 should be
less than ±10.0 Hz
Expected results
Result (circle)
Maximum deviation with GPS signal is less than +/- 1.0 Hz.
PASS FAIL
Maximum deviation without GPS signal is less than +/- 10.0
Hz.
PASS FAIL
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...