2-12
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
2.11 Initial Turn-On
Read and understand the entire initial turn-on procedure before starting. Detailed use of
all GUI screens is given in Section 3 Operation/Alignments.
Shut off the control circuit breaker CB1 and the PS Module breaker (both located
on the bottom front of the transmitter).
Apply primary power to the transmitter at the ac mains disconnect. Be ready to
quickly disconnect the power if necessary.
Turn on the Control circuit breaker, CB1. This should power up the LVPS and bring
up the GUI display. It may be necessary to turn on the LVPS switch (letter “C” in Figure
2-1 on page 2-2). It is located in the back of the transmitter at the top of the controller
assembly.
The GUI display should show the Home (default) screen shown in Figure 2-4. Try using
the touchscreen buttons on the right side of the GUI display (not the hardware buttons
to the right of the GUI). If they do not seem to be working or only work when pressed
outside the button graphic, then go to “5.7 Touch Screen Calibration” on page 3-20
before continuing. If the buttons are working then proceed on to the next step.
Figure 2-4 Home Page
Check the Low Voltage power supplies and AC Mains voltage. Press the POWER
SUPPLY button to access the PS fault and metering screen. Check for +15, -15 and +7.5
volts on LV PSU, with the BUS voltage slightly lower. There should be NO red
indications or faults present. If a fault is present, find the picture of the screen with the
fault in Section 3 for more information.
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...