WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 6 ISP (In-System Programming)
6.3.2
PA Module ISP Procedure
This procedure is only for updating the software in the PA Module(s). The
HarrisISP.exe program must have already been installed on your computer.
IMPORTANT:
This procedure is intended for use on the CZ500F and CZ1000F modules only.
STEP 1
Insert the CD-ROM into the disk drive.
STEP 2
Open the transmitter back door. Connect a standard RS-232 cable from
the serial port on your computer to the DB9 serial connector on the
Backplane Interface board. See Figure 2-1 on page 2-2 for physical
board location.
STEP 3
Run the “Harris ISP.exe” program. The window shown in Figure 6-9
should open.
STEP 4
Set “Port” to the number of the COM port being used on your computer.
STEP 5
Set “Baud” to 9600.
STEP 6
Press Query Micros; wait for system to recognize the 1 or 2 PA Module
micros as shown in Figure 6-10. The micros are at address 33 and 34 so
it will take a minute for them to show up. Note the status indicator at the
bottom left corner of the window. If it does not find the micros, press
Stop Query, change the COM port and press Query Micros again.
Figure 6-9 ISP Opening Screen
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...