12/24/07
888-2685-001
2-11
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
Verify that the patch panel or RF switch has been installed and the proper
jumpers and interlocks are in place. These may vary from site to site.
2.10 PA and PS Module Installation
!
WARNING:
THE PA MODULES AND POWER SUPPLIES ARE LARGE AND RELATIVELY HEAVY,
WEIGHING APPROXIMATELY 17KG. CARE SHOULD BE TAKEN TO AVOID PER-
SONAL INJURY AND/OR DAMAGE TO THE MODULES. PROPER LIFTING TECH-
NIQUES SHOULD ALWAYS BE USED WHEN HANDLING THE MODULES.
The power supply module is installed at the bottom of the cabinet and secured
with two screws. The breaker on the front of the power supply should be set to
OFF.
The PA module(s) are installed and fully seated into the front of the transmitter
cabinet.
NOTE:
For the CZ1000F, the PA Modules should be placed into the same slot in which
they were tested at the factory. Each module has a serial number tag. This serial
number is recorded on the factory test data sheet along with the appropriate slot
number. Placing the module in a different slot will not cause any harm to the
transmitter but will require more time for module phasing.
!
WARNING:
THE RANGER PA MODULES ARE DESIGNED TO HANDLE VERY HIGH TEMPERA-
TURES AND MAY BE EXTREMELY HOT, UP TO 90
O
F (50
O
C) ABOVE ROOM TEM-
PERATURE. DO NOT TOUCH THE MODULES WITH BARE HANDS AFTER THE
TRANSMITTER HAS BEEN RUNNING, ESPECIALLY IN HIGH AMBIENT TEMPERA-
TURE ENVIRONMENTS. SPECIAL GLOVES HAVE BEEN PROVIDED IN THE REAR
OF THE CABINET OR CAN BE OBTAINED FROM HARRIS, PART #0990006483 OR
GRAINGER ITEM #4JF36.
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...