1-8
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Section 1 Introduction
Ranger Commissioning Manual
Each Ranger Series™ PA Module is a self-contained transmitter (except for the power supply)
with its own internal control, monitoring and protection. The modules only receive basic On/Off,
Mute, Restart, Phase and Gain commands from the transmitter control system. This means that
each module will protect itself without relying on the system controller.
1.6
Power Supplies
A 32 Vdc switching power supply is used to provide the DC voltage to the PA modules
within each PA cabinet. The power supply can provide power for 1 or 2 PA modules. The control
system in the PA Cabinet is powered by a self contained low voltage power supply with +/-15Vdc
and +7.5Vdc outputs.
1.7
Apex™ Exciter
For information on setup and operation of the Apex Exciter utilizing FLO
R
technologies refer to
the separate exciter manual, 888-2604-001. The exciter manual is bundled with the transmitter
documentation for shipment.
1.8
General Specifications
Table 1-2 provides the performance specifications for the Ranger series transmitters.
NOTE:
All specifications subject to change without notice
Table 1-2 Ranger Performance Specifications
Item
Unit
s
Conditions
Value
General
Frequency Range
Mhz
Any specified FCC
Channel 14-69
470-806 Mhz
Channel Bandwidth
Mhz
FLO Technologies COFDM standard
6, 7 or 8 Mhz
Output Power before Mask
Filter
W
At 36 dB shoulders (me/-3.00
MHz from center of 6 MHz channel)
CZ500F - 375W
CZ1000F - 750W
RF Load Impedance
Ohms
50 Ohms
RF Load VSWR
Over specified TV channel
1.1:1
Output Connector
1-5/8” EIA Flanged
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...