12/24/07
888-2685-001
2-13
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
Figure 2-5 Power Supply Metering
NOTE:
The PAPS (Power Amplifier Power Supply) readings should be zero and
will be shown as OFF. The PAPS is only active after the transmitter ON
button is pressed. Do not press the transmitter ON button at this time.
Calibrate the AC Mains Reading. Check your ac mains voltage at the disconnect box.
Next press the PS SERVICE button shown in Figure 2-5. This will take you to the
screen in Figure 2-6. Use the +/- buttons at the bottom of the screen to set the AC Mains
voltage to the same as your measured ac voltage. This is a critical adjustment as this
reading is used for the AC low and high fault thresholds.
NOTE:
This calibration should always be done with the transmitter shut off. Adjustment
can cause various power supply faults to appear momentarily including PS Mute.
PA PS: Reading
will be zero at
this time.
Any Power Supply
faults would cause
this icon to turn red