WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
input must be equipped with automatic voltage regulators (optional equipment)
capable of correcting the mains voltage.
The Primary AC conduit is securely attached to the top of the transmitter cabinet.
The top of the transmitter cabinet has a pre-cut hole for a 3/4” conduit connection. For
Conduit connections to the transmitter refer to the Transmitter Outline Drawing 843-
5560-071, Top View. The AC input is the routed straight down to TB1, shown in Figure
2-3.
The AC supply wires have been connected to TB1-2 and TB1-4. The AC Flow
diagram shows ac wiring to the transmitter along with recommended wire gauge and
breaker size. Wire gauge and breaker size are installed as outlined in the Figure 2-
3.
The safety ground wire is attached to one of the terminals on the grounding block.
Figure 2-3 AC and Safety Ground Connections
Verify that the AC wires are securely connected to the primary AC terminal block
TB1. Be sure that the wires are fully seated and that the insulating jacket has not
been pinched between the contact jaws inside the connector.
Safety Ground Connection
TB1 AC Connections
Place flat blade screwdriver into
square hole and gently pry toward
front of transmitter until connector
in round hole is open far enough
to insert the AC input wire
Recommended Wire and
Breaker Sizes:
Model Breaker Wire size
CZ500F 20A 10 awg
CZ1000F 40A 8 awg
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...