Ranger Commissioning Manual
Section 4 RF Testing
4.3.6.2
Performing the Measurement
a.
Open a new terminal by right clicking on the desktop and selecting “New Termi-
nal” from the drop down menu.
b.
Go to the processing main menu by typing:
1.
cd_/local/mnt/pp/automation
2.
./PROCESSING
c.
If the FLO signal parameters have changed since the last capture change the
settings for FLO signal parameters.
d.
Perform the measurements
1.
Enter “1” and press “ENTER”.
2.
Enter the desired number of captures and press “ENTER”.
4.3.6.3
Looking at the Results
a.
Open a new terminal by right clicking on the desktop and selecting “New Termi-
nal” from the drop down menu.
b.
The results are stored in a directory indexed by data and time
c.
Go to the results directory
1.
cd_/local/mnt/pp/results
d.
Go to the indexed directory for the day, month, year of the desired capture
1.
ls -- To list the possible directories
2.
cd_ddMMYYYY
e.
Go to the indexed directory for the hour, minute, second of the desired capture
1.
ls -- To list the possible directories
2.
cd_HHMMSS
f.
Open a file to view its contents
1.
ls -- To view the files in the directory
2.
emacs_filename
4.3.6.4
Moving Results to Flash Drive
a.
Mounting the flash drive
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...