1. Overview

 

Most  modern  Amateur  transceivers  now  generate  their  operating  frequency  from  a  single 
internal  Reference  Oscillator.    In  many  cases,  this  Reference  Oscillator  is  voltage-controlled, 
allowing front panel adjustment of the Reference frequency.  

The  XRef-PLL  locks  the  radio’s  Reference  Oscillator  to  an  external  10  MHz  reference  signal 
from a GPS reference or other high-accuracy source.  It intended to be installed internally within 
the radio.  When no 10 MHz reference is connected, the XRef-PLL completely disconnects from 
the radio, allowing it to operate as from the factory.  

In the case of the Icom IC-756ProIII, the Reference frequency is 32.0 MHz. 

 

2. Technical Specifications

 

Connections to the board are shown below: 

 

 

 

 

 

 

 

 

 

 

Connection  Description 

Specifications 

Test 

Do Not Connect 

 

Lock 

PLL Lock Indicator 

+3.3V 20mA max 

Vp 

Do Not Connect 

 

Gnd 

Power Ground 

 

Vin 

Supply for XRef 

5 to 16 V @ 20 mA 

Ref 

10 MHz Reference Input 

0 to +15 dBm  
(0.5V to 3.6V p-p) 

RF 

Reference frequency from Radio. 

Radio dependent 

Ctl 

Control output to Reference VCXO 

0 to +3.3V 

 

Test 

Lock 

Vp 

Gnd 

Vin 

Ref 

Gnd 

RF 

Gnd 

Ctl 

A Word of Caution: The installation requires a small amount of soldering to very small and 
fragile SMD components.  If you do not have experience with SMD techniques, please seek 
the assistance of someone who does.  We are happy to provide any advice needed, but we 
cannot take responsibility for any damage to your radio. 