22
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
Speed, Flow and RPM Transducer Installation
The HARDI
®
Mustang will work with either the magnetic speed
transducer or proximity speed transducer.
DO NOT USE MAGNETS
WITH THE PROXIMITY TRANSDUCER.
Wiring remains the same for
either speed transducer. For magnetic transducers, the sensor needs
to be placed 5-7 mm from the magnet. For proximity transducers, the
sensor needs to be placed 1.5-3 mm from the magnet mount bracket
(NO MAGNETS USED).
Route the speed sensor cable to the HARDI
®
Sprayer Control Module.
Mate the wires as shown below. Be sure to slide a piece of heat shrink
tubing over each individual wire before mating. Then shrink tubing by
applying heat evenly along tube. Plug the adapter cable into Sprayer
Control Module speed input pigtail with Yellow Cable Tie.
DUPLICATE
THIS FOR FLOW, AND RPM SENSOR INTERFACE.
Blue
Red
Black
White
Brown
Black
Speed, Flow
or RPM
Sensor
3 wire adapter cable
For old infield sprayers, a magnet mount bracket may be required:
10587803 – Magnet Mount Bracket 8-bolt
16020203 – Magnet Mount Bracket 10-bolt
Note: the magnet mount brackets are used with both types of speed
transducers even though magnets are not used with the proximity
speed transducer.
10587803
16020203
Proximity speed transducer