Entering STANDARD Calibration Values
Once in calibration mode, you may change any one, all or none of the
values, in any order. To enter calibration mode, simply turn the rotary
selector to the desired calibration position. Use the ADJUST switch to
adjust values. Calibration positions are identified as RED with white
type (lower six positions).
Entering Standard Calibration
To enter calibration, proceed as follows:
1. Place the AUTO/MAN/HOLD switch in HOLD.
2. Turn the rotary dial to any of the six (RED) calibration positions.
The console will display CAL and the warning light will flash. See
Figure 8.2.
Fig. 8.2
CAL
Exiting System Calibration
Upon completion of the special calibration process, exit special
calibration by simply pressing the SYSTEM CAL button. Proceed with
Standard Liquid Calibration before beginning operation.
Before beginning operation, refer to Test Speed and Pre-field System
Checkout on pages 37 and 38. This will confirm your calibration
settings, nozzle selection and overall system performance.
HARDI MT-9000 OPERATOR’S MANUAL
34