25
HARDI
®
MT-9000 OPERATOR’S MANUAL
Installation: Twin force
RPM and Slot Angle Adjust
First locate the electric over hydraulic control box at the back of the
sprayer and remove cover. Locate the two cables coming from adjacent
box connecting to V7 (slot angle) and V8 (RPM adjust), see picture
below.
Route the two supplied 2-wire 25 foot adapter cables from the Sprayer
Control Module to the electric over hydraulic control box. Be sure to
mark the cables at the fling lead end with colored ties provided. Blue tie
for RPM and gray tie for slot angle. At the electric over hydraulic control
box, insert both adapter cables into hydraulic control box through
separate spare rubber gromets at the bottom of hydraulic control box. Be
sure to strain relief similar to other incoming cables. Pull the brown and
blue wires at V7 from the board (slot angle adjust) and mate them with
the slot angle adjust wires, red to blue and black to brown. Be sure to
slide a piece of heat shrink over wires before mating.
Electric over hydraulic junction box for twin force located on inside of twin
force center section.