51
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
Foam Marker Output from Sprayer Control Module:
Enable the foam marker at the console by pressing the marker On/Off
button and toggle the Left/Auto/Right switch to the right. Place the Master
switch in MAN and toggle at lease one section on.
Using a voltmeter VM, check for +12V between G and E. With the negative
lead touching G and positive to E. Keep the negative lead touching G and
touch the positive lead to D - should be a +12V. With the negative lead
remaining on G, and a jumper (a paper clip works well) between G and C,
touch the positive lead to F. It should measure between 5.8 and 6.8 volts.
If foam rate is set to 0, it will be closer to 6.8 volts, if set to 100,
measurement will be closer to 5.8 volts. Remove jumper. With the negative
lead remaining at G, touch the positive lead to A. This is a 2 hertz signal so
a steady voltage reading will not be measured. However, pulsing should be
visible on the VM if the foam rate is set to 50. Now toggle the
Left/Auto/Right switch to the left and check for +12V at position B with the
negative lead on G.
E
G
F
D
C
B
A