28
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
Entering SYSTEM Calibration Values
The HARDI
®
MUSTANG 3500 has a number of control functions which
are preset at the factory (See Factory Calibration Chart on page 51). In
some cases, however, it may be necessary to change one or more of
these settings to enhance performance or meet special operational
requirements. To make these changes, you need to enter System
Calibration. To enter System Calibration:
1.
Turn the power switch OFF.
2.
Place the AUTO/MAN/HOLD switch in the HOLD position.
3. Place the Rotary switch in the SPEED position.
4.
While pressing the SYSTEM CAL button, turn the power switch ON.
NOTE: The console will display “SYS” (SYSTEM) and “Cal” in the
upper display window. The warning light will flash. See Figure 8.1.
Exiting System Calibration
5.
When all necessary changes have been made, exit SYSTEM CAL.
To do this, press the SYSTEM CAL button. All changes are
immediately saved to memory.
Fig. 8.1
CAL