16
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
AUTO MODE:
To toggle the Angle Mode between AUTO and PRESET,
toggle the mode switch to ANGLE and the MASTER switch to
HOLD and
the ROTARY switch to any calibration position. By then pressing the RESET
button, the Angle mode will toggle between PRESET and AUTO, In the AUTO
mode, the Slot Angle will automatically change from the RATE 1 preset
position to the RATE 3 preset position on a MASTER SWITCH transition from
AUTO to HOLD or on a REMOTE HOLD (foot switch) transition. To adjust the
preset values in the lower left display area place the mode switch in ANGLE
and the MASTER switch in HOLD and the ROTARY switch in any calibration
position, then press the associated RATE button and adjust the value using
the ADJUST switch. In the AUTO mode, the Slot Angle will run to the zero
point (12 seconds forward) and then to the PRESET value every other time
the MASTER switch is toggled from AUTO to HOLD.
SAFETY FEATURE:
To immediately stop Slot Angle movement in either
AUTO or PRESET mode turn the ROTARY SWITCH to any calibration
position.
TEST BUTTON
The TEST button is used to enter the Test Speed mode when calibrating
the system. Refer to Pre-field System Checkout for more information on
Test Speed and using the TEST button.
ADJUST SWITCH
The “+/–” (ADJUST) switch serves many functions within the system, and
can be used within Calibration and Operation (AUTO and MAN).
During normal operation, when the master switch is in automatic (AUTO)
and the rotary dial is not in a calibration position, each toggle of the switch
will increase or decrease the target application rate by the amount of the
calibrated ADJUST RATE.
During normal operation, when the master switch is in manual (MAN),
toggling the ADJUST switch will increase or decrease the application rate
by closing or opening the regulating valve (control valve).
TANK BUTTON
This button is used to check the volume remaining in the tank. To do this,
turn the rotary dial to any of the six operational positions (top half), and
press and hold the TANK button. The top half of the display will show the
volume remaining in the tank. When the TANK button is released, the
display will revert back to the application rate.
The TANK button can also be used to enter a volume into the tank counter.
To do this, press and hold the TANK button and toggle the “ADJUST” switch