38
HARDI
®
MUSTANG 3500 OPERATOR’S MANUAL
Boom Width
Enter the working width, in inches (meters), for the boom section
currently shown on the display. Use the ADJUST switch to adjust the
displayed value to the correct width for the boom number (in the top
display). Turn all booms off, display will read SELEC. Begin with the
farthest right boom switch and work your way left, repeating this
procedure for each boom section.
A value of “0” (.000) must be
entered for any unused boom section.
BOOM WIDTH
PSI
CAL
bar
data
meters
inches
Rate
ERROR
1 2 3
Gal / Ac
kg / ha
Lbs N / Ac
liters / ha
Gal / 1000
Dial position:
Display will read:
Setting Individual Boom Width
In order to accurately measure the number of units applied per acre, it
is important to determine the correct “working” width. The working width
is the width of ground being affected by any operation. This should be
measured to the
nearest inch
(thousandth of a meter).
Your working width will be the number of nozzles on that boom
section times the nozzle spacing in inches (mm).
For example, if
you have 7 nozzles spaced at 20 inches, the working width is 140
inches.
ADDITIONAL BOOM WIDTH FEATURE:
To adjust the constant pressure distribution valves, first toggle the
master switch to MAN and the rotary switch to Non-Cal position and
using the adjust switch, adjust the pressure regulating valve to your
target application pressure. After reaching target pressure, rotate rotary
switch to boom width position. After 5 seconds the output to each
distribution valve will be electronically isolated allowing the distribution
valve to be operated manually to adjust bypass to maintain constant
pressure when distribution valve is turned off.