Media-Mate Plus Operation Manual
25-710-800-O
Section Seven – Operating Instructions
Volume Selection
See
Figures 6-1
and
6-2
.
1.
Loosen the Upper Lock Screw so that the Dispense Tube may be moved.
2.
Grasp the Pointer handle and rotate 45
°
in either direction.
3.
Raise or lower the Dispense Tube as necessary to align the Pointer with the appropriate
incremental standard notch.
NOTE:
The incremental standard has been marked with a volumetric scale so that the
appropriate notch may be readily located.
4.
Rotate the Pointer handle until the Pointer engages the incremental standard notch.
5.
Move the Pointer down tight against the lower side of the notch and tighten the Upper
Lock screw.
6.
Repeat Steps 1 through 5 for each vessel position.
Temperature Setting
See
Figure 5-3
.
The Temperature Controller is located in the approximate center of the Control Panel. The
Temperature Controller has two digital displays that display in tenths of a degree. The upper
display shows actual media temperature while the lower display shows Set Point Temperature.
To Set Temperature:
1.
Verify that the media Tank has been filled to at least the 18-liters mark.
2.
Verify that the Heater Assembly is installed in the Tank and is plugged into the Interface
Panel.
3.
Plug the retractable power cord into an appropriate AC power receptacle (see
Section 5
– “Electrical”
for retracting requirements of cordage).
4.
Turn on Heater power and Air Pump power at the Control Panel.
5.
Increase or decrease Set Point Temperature using the “UP”/”DOWN” Arrow Keys located
just below the Set Point Display on the Temperature Controller. Allow adequate time for
the temperature to stabilize.
Section 7
Operating Instructions