Operation Manual – Location Server Configuration
H3C XE 200/2000 IP PBX
Chapter 4 XE IP PBX Troubleshooting
4-7
Solution
: In LS-GW view, use the
manufacturer
command to set the manufacturer to
h3c
.
III. UA fails to register with the LS
1)
Cause 1
: The IP address and port number for the UA configured on the LS do not
match those configured on the UA.
Diagnosis
: Use the
display location-server gateway xxx
command to check the
dynamic information on the LS (xxx corresponds to the device identifier of the UA). If
the registration status is offline, the registration fails. Use the
display
current-configuration
command to check in LS-GW view if the IP address and port
number are consistent with those configured on the UA.
Solution
: On the LS, configure the IP address and port number for the UA in LS-GW
view, making them consistent with those configured on the UA.
2)
Cause 2
: If the authentication of the UA registration is enabled on the LS, the
authentication password or default password in LS-GW view is inconsistent with
that configured on the UA.
Diagnosis
: Use the
authentication enable
command to check if the authentication is
enabled in LS-GW view. If yes, check if the configured password is consistent with that
configured on the UA.
Solution 1
: In LS-GW view, use the
password
command to configure the password,
making it consistent with that configured on the UA.
Solution 2
: In LS-GW view, use the
authentication disable
command disable the
authentication.
4.2.3 Troubleshooting SIP Redirect Server
I. The redirect server is unreachable from the UA
Cause
: Similar to
4.2.1 I.
“
The proxy server is unreachable from the SIP UA
”.
Diagnosis
: Similar to
4.2.1 I.
“
The proxy server is unreachable from the SIP UA
”.
Solution
: Similar to
4.2.1 I.
“
The proxy server is unreachable from the SIP UA
”.
II. The redirect server is reachable from the UA, but calls cannot be set up
Cause
: Similar to
The proxy server is reachable from the SIP UA, but calls cannot be
set up
.
Diagnosis
: Similar to
The proxy server is reachable from the SIP UA, but calls cannot
be set up
.
Solution
: Similar to
The proxy server is reachable from the SIP UA, but calls cannot be
set up.
Содержание XE 200/2000 IP
Страница 7: ...Basic Configuration ...
Страница 42: ...Process Server Configuration ...
Страница 82: ...Location Server Configuration ...
Страница 182: ...Feature ...
Страница 259: ...System Management ...
Страница 341: ...IP Performance and Application ...
Страница 349: ...Media Server ...
Страница 360: ...Call Services ...
Страница 507: ...Appendix A ...
Страница 511: ...Appendix B ...