[XE] process-server
[XE-ps] ps-config xe200 interface Ethernet 0/0
[XE-ps] heartbeat password xe200
[XE-ps] ls-mode 0 local
[XE-ps] start
[XE-ps] sip
[XE-ps-sip] start
# Configure the LS.
[XE] location-server
[XE-ls] ls-config interface Ethernet 0/0 port 13579
[XE-ls] call-mode sip routed
[XE-ls] start
[XE-ls] process-server xe2000
[XE-ls-ps-xe2000] heartbeat password xe200
[XE-ls] gateway router1
[XE-ls-gw-router1] device-type sip
[XE-ls-gw-router1] dynamic-ip enable
[XE-ls-gw-router1] quit
[XE-ls] gateway router2
[XE-ls-gw-router2] device-type sip
[XE-ls-gw-router2] dynamic-ip enable
3.7 Separate Implementation of LS and SIP Proxy Server
I. Network requirements
The LS and SIP proxy server are implemented on two XE IP PBXs respectively. Two
voice gateways function as SIP UAs for SIP calls by the SIP proxy server and the proxy
server acquires information about the called party through the LS.